Siemens RUGGEDCOM RSG908C Installation Manual page 44

Rugged ethernet switches
Hide thumbs Also See for RUGGEDCOM RSG908C:
Table of Contents

Advertisement

61000-4-9
61000-4-11
61000-4-16
61000-4-17
61000-4-18
61000-4-29
60255-27
EMC Immunity Type Tests per IEEE 1613
Note
The RUGGEDCOM RSG908C meets Class 2 requirements for an all-fiber configuration
and Class 1 requirements for copper ports. Class 1 allows for temporary communica-
tion loss, while Class 2 requires error-free and interrupted communications.
RUGGEDCOM RSG908C
Installation Manual, 02/2020, C79000-G8976-1404-06
Test
IEC
Pulse Magnetic Field
IEC
Voltage Dips and Interrupts
IEC
Mains Frequency Voltage
IEC
Ripple on DC Power Supply
IEC
Damped Oscillatory Wave
IEC
Voltage Dips and Interrupts
IEC
Dielectric Strength
HV Impulse
Test
IEEE 1613
IEEE 1613
IEEE 1613
6.2 EMC and Environmental Type Tests
Description
Enclo-
sure Ports
AC Pow-
er Ports
Signal Ports
DC Pow-
er Ports
DC Pow-
er Ports
Slow
Damped
DC Pow-
er Ports
Signal Ports
DC Pow-
er Ports
AC Pow-
er Ports
Signal Ports
DC Pow-
er Ports
AC Pow-
er Ports
Description
ESD
Enclosure Contact
Enclosure Air
Radiated RFI
Enclosure Ports
Fast Tran-
Signal Ports
sient
DC Power Ports
AC Power Ports
Earth Ground Ports
Test Levels
300 A/m
30% for 0.5 Cycles
60% for 5 Cycles
100% for 250 Cycles
30 V Continuous
300 V for 1 s
30 V Continuous
300 V for 1 s
15%
2.5 kV Common
100 kHz or 1 MHz
30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
2 kV (Failsafe Relay Output)
2 kV or 2.8kV DC
2 kV
5 kV (Failsafe Relay Output)
5 kV
5 kV
Test Levels
± 8 kV
± 15 kV
35 V/m
± 4 kV @ 2.5 kHz, 5 kHz
± 4 kV @ 2.5 kHz, 5 kHz
± 4 kV @ 2.5 kHz, 5 kHz
± 4 kV
Certification
Severi-
ty Levels
4
 
4
4
4
3
 
 
 
 
 
 
 
35

Advertisement