IXIO-S CAN: INSTALLATION GUIDE
1
MOUNTING & WIRING
Plug the connector with the WHITE and
GREEN wires on top towards the sensor cover.
2
INFRARED SAFETY FIELD
2x
Activate the visible* spots to verify
the position of the IR-curtain.
W W
Part of the detection field can be masked to reduce it.
the arrow position determines the width of the detection field.
Mounting
Detection
height
width
2.00 m
2.00 m
2.20 m
2.20 m
2.50 m
2.50 m
3.00 m
d max
3.50 m
d max
CLOSER
AWAY
If necessary, adjust the IR-curtain
angle (from -7° to 4°, default 0°).
* Visibility depends on external conditions. When spots are not visible, use the Spotfinder to locate the curtains.
** the distance between the inner curtain of the inside door sensor and the inner curtain of the outside door sensor should
always be smaller than 20 cm. the distance to the door leaf depends therefore on the thickness of the door leaf.
W
N
N
W
3.50 m
3,50 m
EN 16005
DIN 18650
BS 7036
3 m
3 m
2.50 m
2,50 m
2 m
2 m
d max = 2.5 m
d max = 2,5 m
GREEN
BROWN
YELLOW
WHITE
N N
Always verify the actual detection field width
with a piece of paper and not the Spotfinder,
which detects the whole emitted field.
3.50 m
3,50 m
the size of the detection field varies according to the
3 m
3 m
2,50 m
2.50 m
2 m
2 m
d max = 3 m
POWER
+
-
SUPPLY
CAN HIGH
CAN LOW
max.
9 cm**
tIP!
Additional
adjustments
are possible
(see p. 5)
mounting height and the settings of the sensor.
the full door width must be covered.