IXIO-SO1 I: INSTALLATION GUIDE
1
MOUNTING & WIRING
TIP!
Wiring is compatible with the IRIS.
2
INFRARED SAFETY FIELD
OR
Activate the visible* spots to verify
the position of the IR-curtain.
Part of the detection field can be masked to reduce it.
The arrow position determines the width of the detection field.
CLOSER
AWAY
If necessary, adjust the IR-curtain
angle (from -7° to 4°, default 0°).
* Visibility depends on external conditions. When spots are not visible, use the Spotfinder to locate the curtains.
The size of the detection field varies according to the mounting height and the settings of the sensor.
GREEN
12-24 V
BROWN
AC-DC
YELLOW
*
WHITE
PINK
*
GREY
RED
BLUE
* Output status when sensor is operational
Always verify the actual detection field width
with a piece of paper and not the Spotfinder,
which detects the whole emitted field.
The full door width must be covered.
POWER SUPPLY
OPENING INPUT
SAFETY INPUT
NOT USED
DOOR
max.
9 cm
Additional
adjustments
are possible by
LCD or remote
control
(see p. 5)