IXIO-SO1 I: INSTALLATION GUIDE
1
MOUNTING & WIRING
Mount the sensor securely.
2
INFRARED PRESENCE FIELD
OR
Activate the visible* spots to verify
the position of the IR-curtain.
Part of the detection field can be masked to reduce it.
The arrow position determines the width of the detection field.
CLOSER
CLOSER
AWAY
AWAY
If necessary, adjust the IR-curtain
angle (from -7° to 4°, default 0°).
* Visibility depends on external conditions. When spots are not visible, use the Spotfinder to locate the curtains.
The size of the detection field varies according to the mounting height and the settings of the sensor.
RED
+
-
BLACK
YELLOW
*
YELLOW
PINK
*
PINK
BLUE
BLUE
* Depending on OUTPUT CONFIGURATION settings
Always verify the actual detection field width
with a piece of paper and not the Spotfinder,
which detects the whole emitted field.
The full door width must be covered.
DOOR CONTROLLER
POWER SUPPLY
OPENING
PRESENCE
NOT USED
DOOR
max.
9 cm
Additional
adjustments
are possible by
LCD or remote
control
(see p. 5)