A 30 A maximum rated, certified wall circuit breaker is required. It must be part of the building
and easily accessible.
Use a minimum of 12 AWG copper wire, grounding included, for the connection of the main AC
supply to the projector's ground lug.
Either copper or aluminum is acceptable as conductor wiring material to the terminal block.
A
200-240 V main inlet
B
100-240 V secondary or UPS inlet
C
UPS circuit breaker
D
MAIN input circuit breaker
1. Remove the four screws holding the AC receptacle knockout plate.
The AC supply is routed to the terminal block through an appropriate strain relief mounted on
this knockout plate.
CP2315-RGB Installation and Setup Guide
020-102772-02 Rev. 1 (05-2019)