Install Air Restrictors; Re-Install Rear Log Support - Valor H4 Series Installation & Owner's Manual

Direct vent natural/propane gas
Table of Contents

Advertisement

Install Air Restrictors

No restrictors are required for appliances which only have a horizontal vent run.
If installing an appliance which has a rear vent outlet connection and no vertical
vent pipe rise, ignore this stage.
Two restrictor sets, like the one shown at right, are supplied with each 650 engine unit.
The restrictors cover part of the inlet air openings in the fi rebox rear wall behind the
rear log support. Do NOT install the restrictors in the roof of the fi rebox!
Each restrictor set includes an adjustable piece which can be moved to diff erent
positions depending of the vent confi guration. See the table below to fi nd out which
position is optimal for each type of installation.
• To fi t the restrictors, loosen the two center screws of the left and right inlet ports.
Place the restrictor assembly under the screw heads and tighten the center screws.
• To set the adjustable restrictor piece, loosen the two screws, position the adjustable
piece according to the diagram below and tighten the screws.
Appliance
Vent terminal
vent outlet
Horizontal
Top or Rear
Less than
through wall
6' (183 cm)
with vertical
rise
From
6' (1.83 m) to
No vertical
20' (6.1 m)
rise = NO
restrictor
From
20' (6.1 m) to
40' (12.2 m)
Appliance
Vent terminal
vent outlet
Vertical
Top or rear
Less than
through roof
20' (6.1 m)
From
20' (6.1 m) to
40' (12.2 m)

Re-install Rear Log Support

Refi t the rear log support in place (5 screws).
Installation
Vertical vent
Use restrictor
pipe run
setting
Vertical vent
Use restrictor
pipe run
setting
Air Restrictor Assembly
DO NOT INSTALL HERE!
INSTALL HERE