Jungheinrich ESD 220 Operating Instructions Manual page 114

Industrial truck
Table of Contents

Advertisement

8.4.10
Setting the automatic truck cutout (timeframe)
Requirements
– To prepare the truck for operation, see page 101.
Procedure
• Press the O key (93).
• Enter the valid master code with the digit keys.
When you enter the correct master code the LED
(92) flashes green.
• Enter the 0-1-0 parameter with the digit keys.
• Confirm with the SET key (91).
Wait until the LED (92) flashes green.
• Set the truck automatic cutout (time period) with the digit keys:
• 00:
Automatic truck cutout is deactivated.
• 01 - 30:
Set time period (in minutes) after which the truck automatically cuts out
(minimum cutout time is 1 minute,
maximum cutout time is 30 minutes).
• 31:
After 10 seconds the truck cuts out automatically.
• Confirm with the SET key (91).
Wait until the LED (92) flashes green. The setting is saved.
• Press the O key (93).
The truck is switched off and the LED (92) lights up red.
• Checking the truck's automatic cutout:
• Switch on the truck with a valid operator code, see page 101.
When you have entered a valid operator code the LED (92) lights up green, the
travel program selected is indicated by the corresponding LEDs (88,89,90) and
the truck is switched on.
• Do not perform any travel, steering or hydraulic operations with the truck.
• Wait until the truck automatically cuts out at the end of the time period.
The truck is switched off and the LED (92) lights up red.