Danfoss FC 102 Operating Manual page 77

Vlt hvac drive, 355–800 kw, enclosure size e
Hide thumbs Also See for FC 102:
Table of Contents

Advertisement

Specifications
Normal overload
(Normal overload=110% current during 60 s)
Typical shaft output at 400 V [kW]
Typical shaft output at 460 V [hp]
Typical shaft output at 480 V [kW]
Enclosure size
Output current (3-phase)
Continuous (at 400 V) [A]
Intermittent (60 s overload)
(at 400 V) [A]
Continuous (at 460/480 V) [A]
Intermittent (60 s overload)
(at 460/480 V) [A]
Continuous kVA (at 400 V) [kVA]
Continuous kVA (at 460 V) [kVA]
Continuous kVA (at 480 V) [kVA]
Maximum input current
Continuous (at 400 V) [A]
Continuous (at 460/480 V) [A]
Maximum number and size of cables per phase (E2h)
- Mains and motor without brake [mm
- Mains and motor with brake [mm
2
- Brake or regeneration [mm
(AWG)]
Maximum number and size of cables per phase (E4h)
2
- Mains and motor [mm
(AWG)]
- Brake [mm
2
(AWG)]
1)
- Load share or regeneration [mm
Maximum external mains fuses [A]
Estimated power loss at 400 V [W]
Estimated power loss at 460 V [W]
4)
Efficiency
Output frequency
Heat sink overtemperature trip [°C (°F)]
Control card overtemperature trip [°C (°F)]
Power card overtemperature trip [°C (°F)]
Fan power card overtemperature trip [°C (°F)]
Active in-rush card overtemperature trip [°C (°F)]
Table 9.2 Technical Specifications, Mains Supply 3x380–480 V AC
1) American Wire Gauge.
2) For fuse ratings, see chapter 9.7 Fuses.
3) Typical power loss is at normal conditions and expected to be within
values are based on a typical motor efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the drive. Applies for
dimensioning of drive cooling. If the switching frequency is higher than the default setting, the power losses can increase. LCP and typical control
card power consumptions are included. For power loss data according to EN 50598-2, refer to www.danfoss.com/vltenergyefficiency. Options and
customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for slots A and B each add only 4 W.
4) Measured using 5 m (16.4 ft) shielded motor cables at rated load and rated frequency. Efficiency measured at nominal current. For energy
efficiency class, see chapter 9.4 Ambient Conditions. For part load losses, see www.danfoss.com/vltenergyefficiency.
MG16O102
Operating Guide
2
1)
(AWG)]
2
(AWG)]
1)
1)
1)
2
(AWG)]
1)
2)
3) 4)
3)4)
Danfoss A/S © 01/2017 All rights reserved.
N500
NO
500
650
560
E2h/E4h
880
968
780
858
610
621
675
848
752
6x240 (6x500 mcm)
5x240 (5x500 mcm)
2x185 (2x350 mcm)
6x240 (6x500 mcm)
2x185 (2x350 mcm)
4x185 (4x350 mcm)
1200
9473
7809
0.98
0–590 Hz
110 (230)
80 (176)
85 (185)
85 (185)
85 (185)
± 15% (tolerance relates to variety in voltage and cable conditions.) These
N560
NO
560
750
630
E2h/E4h
990
1089
890
979
686
709
771
954
848
6x240 (6x500 mcm)
5x240 (5x500 mcm)
9
2x185 (2x350 mcm)
6x240 (6x500 mcm)
2x185 (2x350 mcm)
4x185 (4x350 mcm)
1200
11102
9236
0.98
0–590 Hz
100 (212)
80 (176)
85 (185)
85 (185)
85 (185)
75