EcoWater ETF2300PF10 Owner's Manual

EcoWater ETF2300PF10 Owner's Manual

Multi-purpose filter

Advertisement

OWNER'S MANUAL
How to install, operate and maintain your
Models
ETF2300PF10
ETF2300PF12
Systems tested and certified without media
by the Water Quality Association against
CSA B483.1, NSF/ANSI Standard 61, and
NSF/ANSI Standard 372 for low lead content.
Designed, Engineered &
Assembled in the U.S.A.
EcoWater Systems
Multi-purpose Filter
EcoWater Systems LLC
P.O. Box 64420, St. Paul, MN 55164-0420
www.ecowater.com
7355260 (Rev. B 7/3/17)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ETF2300PF10 and is the answer not in the manual?

Questions and answers

Mark Blose
February 6, 2025

top distributor I can not remove from tank. any suggestions?

1 comments:
Mr. Anderson
February 10, 2025

To remove the top distributor from the EcoWater ETF2300PF10 tank, follow these steps:

1. Remove the unit’s top cover.
2. Unplug the wiring connections between the valve and the control board (PWA).
3. Remove the retainer clips and clamp sections from the tank neck.
4. Carefully lift the valve off the tank.

This will allow access to the top distributor for removal or replacement.

This answer is automatically generated

Summary of Contents for EcoWater ETF2300PF10

  • Page 1 Systems tested and certified without media by the Water Quality Association against CSA B483.1, NSF/ANSI Standard 61, and NSF/ANSI Standard 372 for low lead content. EcoWater Systems LLC Designed, Engineered & P.O. Box 64420, St. Paul, MN 55164-0420 Assembled in the U.S.A.
  • Page 2: Table Of Contents

    Check local plumbing and electrical codes. The Changes or modifications not expressly approved by installation must conform to them. EcoWater Systems could void the user’s authority to Use only lead-free solder and flux for all sweat-solder operate the equipment. connections, as required by state and federal codes.
  • Page 3: Specifications & Dimensions

    ECOWATER Specifications & Dimensions S Y S T E M S SPECIFICATIONS Model ETF2300PF10 ETF2300PF12 Model Code HPF10 HPF12 Sediment Removal factory recommendation limits: (Filter Aggregate) based on water analysis Acid Neutralizer water supply pH 6.0 - 6.8 pH 6.0 - 6.8...
  • Page 4: Before Starting Installation

    Also inspect and note any dam- age to the shipping carton. Notify the transportation TOOLS, PIPE & FITTINGS, company if damage is present. EcoWater Systems is not responsible for in-transit damages. OTHER MATERIALS YOU WILL NEED...
  • Page 5: Media Loading

    MEDIA LOADING Riser Pipe Top Edge of Top Distributor Models ETF2300PF10 & ETF2300PF12, as manufac- 0” to 1/2” tured, have no media other than quartz gravel at the bottom of the tank. Before plumbing the unit, load fil- ter sand and mineral (See table on Page 3 for amounts): 1.
  • Page 6: Typical Installation Illustrations

    ECOWATER Typical Installation Illustrations S Y S T E M S INSTALLATION USING ECOWATER BYPASS VALVE CROSS-OVER Use if water supply flows from the left. Filtered Include single or 3-valve bypass. Water OUT UNFILTERED FILTERED WATER WATER Unfiltered Water IN...
  • Page 7: Installation

    ECOWATER Installation S Y S T E M S 1. TURN OFF WATER SUPPLY Clip (2) a. Close the main water supply valve near the well 1” Copper Tube OUTLET pump or water meter. (install in filter valve or bypass valve) b.
  • Page 8 4a or 4b following. 7. CONNECT TO ELECTRICAL POWER: a. Use the EcoWater ground clamp kit (not included) to make a jumper across the inlet and outlet pipes The filter controller works on 24V DC electrical power.
  • Page 9: General Information

    The sanitizing bleach and any air remaining in the unit are purged to the drain. Pour about 1 oz. (for ETF2300PF10), or 2 oz. (for ETF2300PF12), of the following disinfectant into the The filter returns to service in about 30 minutes. After...
  • Page 10 “Connected” and gives you a key code. If not, you may need to cancel and use When the EcoWater Systems filter is plugged in for the the browser option. first time, a beep sounds and the display briefly shows a logo, followed by model information.
  • Page 11: Setup Procedure

    14. Once the key code is displayed (it may take a few seconds) , write it down. It will be used when you 9. On your laptop, register your system on the EcoWater web site. tablet or phone, NOTE: If the “Connected” message shows “- - - - - -”...
  • Page 12 ECOWATER Setup Procedure S Y S T E M S continued from the previous page System information Wireless information DSN: AC000W000009876 Iron (parts per million) Model information No. of People 1 - 2 3 - 4 5 - 7 8 - 20...
  • Page 13 In the verification screen, click the “logging in” link (or go to http://wifi.ecowater.com). EcoWater Wi-Fi web site. If a system is not shared, the dealer only has access to the “Dealer Communication 7. Log in with the e-mail and password that you entered Preferences”...
  • Page 14: Filter Operation

    The filter status screens described in the previous sec- tion will not be displayed in a rolling sequence when During normal operation, the EcoWater Systems filter’s one of the following items is displayed: display shows up to four status screens. Page 19 Recharge status (Displayed during recharges, explains how individual screens can be turned on or off.
  • Page 15 ECOWATER Filter Operation S Y S T E M S MAIN MENU SETTING THE CURRENT TIME When the filter’s electronic control is first powered up, a Main menu “wizard” screen prompts you to set the current time Recharge (See Pages 10-12). To change the time at a later date,...
  • Page 16 ECOWATER Filter Operation S Y S T E M S LOCKOUT FEATURE A “lockout” feature is available to prevent user modifica- When the lockout feature is on, the flashing padlock tion of parameters that affect filter performance. The icon will appear in any screen that would normally be unit is shipped from the factory with the lockout feature used to change a parameter in the list to the left.
  • Page 17 ECOWATER Filter Operation S Y S T E M S RECHARGING THE FILTER This feature may be used to assure an adequate supply 5. Press the SELECT ( ) button. If Recharge now is of conditioned water at times of unusually high water selected, the display immediately goes to the use.
  • Page 18 ECOWATER Filter Operation S Y S T E M S SETTING MAXIMUM DAYS BETWEEN RECHARGES When the filter’s electronic control is first powered up, a Iron (parts per million) No. of “wizard” screen prompts you to set the number of days...
  • Page 19 ECOWATER Filter Operation S Y S T E M S SETTING RECHARGE TIME MODIFYING ROLLING SCREENS When the filter’s electronic control is first powered up, During normal filter operation, up to four status screens the default time for starting an automatic recharge is are shown in sequence (See “Filter Status Screens”...
  • Page 20 ECOWATER Filter Operation S Y S T E M S SETTING THE LANGUAGE SETTING TIME FORMAT When the filter’s electronic control is first powered up, a Use this feature to select a 12-hour (AM/PM) or 24-hour “wizard” screen prompts you to set the language (See clock.
  • Page 21 ECOWATER Filter Operation S Y S T E M S SYSTEM INFORMATION Model information Use these features to look up the following information about the filter and its operations: Model: HPF10 Model information (model number and software version) Version: T2.0 Wireless information FIG.
  • Page 22 ECOWATER Filter Operation S Y S T E M S CYCLE TIMES Use these features to change the following filter opera- 8c. Backwash time: Press the UP (5) or DOWN tions: (6) buttons to change the backwash time. Hold the button down to rapidly advance. The...
  • Page 23 ECOWATER Filter Operation S Y S T E M S 8a. Fill time: Press the UP (5) or DOWN (6) but- ber of months until the next service reminder. Set or tons to change the fill time. Hold the button reset the service reminder as follows: down to rapidly advance.
  • Page 24 CHEMICAL FEED* equipment in water treatment systems, consult the If the auxiliary control mode has been set to Chemical EcoWater Systems “Problem Water Guide.” feed, as described in the previous section, two addition- To select an auxiliary control mode: al lines (Chemical feed volume and Chemical feed 1.
  • Page 25 ECOWATER Filter Operation S Y S T E M S DIAGNOSTICS This feature allows a service technician to check the 10. When finished viewing the Diagnostics screen, operating state of individual components in the filter press the SELECT ( ) button. The display will go (e.g.
  • Page 26: Service Information

    5. Add the recommended amounts of gravel, filter sand, and activated carbon mineral. See Suggested Model “Specifications” on Page 3. Freeboard 6. Do Steps 10 & 11, above. ETF2300PF10 15” ETF2300PF12 16” Plug When Adding Mineral Mineral Mineral...
  • Page 27 S Y S T E M S RELIEVING WATER PRESSURE WITH THE BYPASS VALVE(S) CAUTION: Always relieve water pressure in the EcoWater Systems filter, as described below, before removing parts from the valve or media tank. DE-PRESSURIZE 1. Put bypass valve(s) into Bypass position.
  • Page 28: Troubleshooting Guide

    TROUBLESHOOTING - INITIAL CHECKS Always make these initial checks first: 5. Are inlet and outlet pipes connected to the EcoWater filter inlet and outlet respectively? 1. Is display blank? Check power source. 6. Is valve drain hose free of kinks and sharp bends, 2.
  • Page 29 ECOWATER Service Information S Y S T E M S AUTOMATIC ELECTRONIC DIAGNOSTICS CHECKING THE TURBINE 1. Display the Diagnostics screen, following the proce- This filter has a self-diagnostic function for the electrical dure on Page 25. system (except for input power and/or water meter).
  • Page 30 ECOWATER Service Information S Y S T E M S TROUBLESHOOTING - 10. With the Diagnostics screen displayed, once again press the RIGHT (4) button to advance the MANUAL ADVANCE RECHARGE CHECK valve to Fast Rinse. Again, look for a drain flow Use the following procedures to advance the filter rate about the same as backwash.
  • Page 31 ECOWATER Service Information S Y S T E M S SERVICE Valve Cam Position Switch FIG. 102 FILL Valve Cam Position Switch FIG. 103 BRINE DRAW Valve Cam Position Switch FIG. 104 BACKWASH Valve Cam Position Switch FIG. 105 FAST RINSE...
  • Page 32 ECOWATER Notes S Y S T E M S...
  • Page 33: Repair Parts

    0501783 Filter Sand, 10 lbs. Ù 7124415 Gravel, 17 lbs. 7248706 Ground Clamp Kit Ù Ù Not included with the filter. To order parts, call your local EcoWater dealer or go to www.ecowater.com to locate a dealer in your area.
  • Page 34 ECOWATER Repair Parts S Y S T E M S VALVE EXPLODED VIEW flow plug assembly assembled view wear strip seal cross-section view...
  • Page 35 Bypass Valve, 1” Ù (includes 2 ea. 7214383 7129889 Spring of Key Nos. 70 & 72) Ù Not included with the filter. To order parts, call your local EcoWater dealer or go to www.ecowater.com to locate a dealer in your area.
  • Page 36: Warranty

    Should you need service, your local, independent EcoWater Dealer is only a phone call away. PHONE:____________________________________________________________ To obtain warranty service, notice must be given, within thirty (30) days of the discovery of the defect, to your local EcoWater Systems dealer.

This manual is also suitable for:

Etf2300pf12Hpf10Hpf12

Table of Contents