  • Page 1 SERIES 3000 & 3002 P/N: 7283586...
  • Page 2 OWNERS MANUAL How to maintain and operate your EcoWater Systems digital demand water conditioner EcoWater Systems Conditioner with Remote (ECR) EcoWater Systems Refiner with Remote (ERR) SERIES 3000 & 3002 Systems Tested and Certified by NSF International and ERR 3000R20 & ERR 3002R30 are Tested and Certi-...
  • Page 3: Table Of Contents

    Check local plumbing and electrical codes. The installation must conform to them. Use only lead- -free solder and flux for all sweat--solder connections, as required by state and federal codes. Use care when handling the EcoWater Systems conditioner. Do not turn upside down, drop, or set on sharp protrusions.
  • Page 4: Warranty

    Are any additional warranties available? accordance with this guarantee. We are pleased to say, YES! EcoWater Systems LLC sells an EXTENDED, PARTS ONLY WARRANTY for the ELECTRONICS portion of your product. This warranty is called the “Perfect Ten” and extends the five year warranty on the...
  • Page 5: Water Conditioning

    Hardness, (2) Iron, (3) Sediments, (4) Barium and low or brown as air oxidizes the iron. This usually (5) Radium 226 and 228. These are described be- occurs in 15 to 30 minutes. An EcoWater Systems low: conditioner will remove moderate amounts of this type of iron (see specifications).
  • Page 6: Planning Installation

    INLET - - OUTLET PLUMBING OPTIONS FIGURE 2 - - DRAIN OPTIONS drain drain hose S ALWAYS INSTALL either an EcoWater Systems hose bypass valve #7214383, or a 3 valve bypass sys- tem. Bypass valves allow you to turn off water to 1- -1/2”...
  • Page 7: Installation

    2. TURN OFF WATER SUPPLY TUBES a. Close the main water supply valve, near the well a. IF INSTALLING AN ECOWATER SYSTEMS BY- pump or water meter. PASS VALVE, put lubricated o--ring seals onto both b. Shut off the electric or fuel supply to the water bypass valve ports (FIGURE 3B).
  • Page 8 FIGURE 6 FIGURE 4 FIGURE 5 3 - - Valve Bypass BYPASS OUTLET INLET nozzle & VALVE VALVE VALVE venturi EcoWater Systems Bypass Valve ground clamp o- -ring brine from conditioner elbow to conditioner tubing PULL OUT for service nut- -ferrule...
  • Page 9: Install Brine Tank

    EcoWater salt. Systems conditioner. Any air remaining in the unit is purged to the drain. 11. SANITIZING THE ECOWATER SYSTEMS CONDITIONER COMPLETE THE PROGRAMMING STEPS ON PAGES 9 AND 10. Care is taken at the factory to keep your EcoWater System conditioner clean and sanitary.
  • Page 10: Programming Digital Demand Faceplate Controller

    ECOWATER Programming the Digital Demand Faceplate Controller Y S T ↑ display keypad SALT LEVEL keypad SELECT/EXIT RECHARGE keypad keypad ↓ keypad TANK LIGHT keypad THE FOLLOWING STEPS ARE FOR FIRST TIME SET UP ONLY. When the transformer is plugged in, a ‘‘beep’’ will sound, followed by the factory set model code dis- play and software version for a few seconds.
  • Page 11 This recharge draws the bleach (see back of remote. When the remote is receiving this step 11, page 8) through the EcoWater Systems signal, the LED’s will flash red, amber, green. Now conditioner to sanitize it and to purge any air re- remote can be placed in a convenient location.
  • Page 12: Faceplate Controller, Features/Options

    F If the unit is in recharge, the display will show remaining time in recharge and current stage of recharge. PROGRAM MEMORY: If electrical power to the EcoWater Systems conditioner goes off, the display is blank, but the faceplate controller keeps the correct time for at least two days. When electrical power comes on again, you have to verify clock time is correct.
  • Page 13 Cancel Recharge Tonight. Press SELECT/EXIT keypad to return to Normal Screen Views. When this feature is set, the EcoWater Systems conditioner will regenerate at the next programmed start time. This feature is beneficial to assure a sufficient supply of conditioned water for expected heavy water usage the next day.
  • Page 14 ECOWATER Faceplate Controller, Features/Options Y S T Primary Menu, continued Water Flow Rate: Enter Primary Menu. Press the (↑) or (↓) keypads until cursor is next to Water Flow Rate. Press the SELECT/EXIT (↵ ) keypad. When selected, this screen will show the water flow rate in gallons per min- ute (GPM) or liters per minute (LPM) with the moving bar graph at the bot- tom of the display.
  • Page 15 ECOWATER Faceplate Controller, Features/Options Y S T Primary Menu, continued Remote Status: Enter Primary Menu. Press the (↑) or (↓) keypads until cur- sor is next to Remote Status. Press the SELECT/EXIT ( ↵ ) keypad. The current remote status is displayed. Send E.A.S.E.
  • Page 16 SELECT/EXIT (↵) to exit. Warning screen will appear after changing model code, press (↑) to continue. The display will return to the start--up screens. MODEL NUMBER Required Code Alternate Code (on rating decal) ECR 3000R20 ERR 3000R20 R20+ E20+ ECR 3000R30 ECR 3002R30 2R30...
  • Page 17: Remote Monitor Features / Options, Fcc

    If LED’s do not light, batteries need to be changed. If there is another EcoWater Systems conditioner within range of the remote, it may cause a conflict with the channel that the remote monitor is receiving. If the remote monitor displays the wrong message (example: low salt when salt is above warning level) this is an indication that the remote monitor is receiving a different signal.
  • Page 18: Service Information

    A clean nozzle and venturi (FIGURE 7) is a must for age level frequently. If the conditioner uses all the the EcoWater Systems conditioner to work right. salt before you add more, you will get hard water. Be This small unit creates the suction to move brine sure the brinewell cover is on when adding salt.
  • Page 19 (PC). The PC processes the data to determine if all electrical functions are working normally, or helps to identify a problem should one occur. Ask your participating EcoWater Systems dealer for more information on this feature.
  • Page 20: Troubleshooting

    ECOWATER Service Information Y S T AUTOMATIC ELECTRONIC DIAGNOSTICS The chart below shows the error codes that could appear, and the possible defects for each code. The faceplate computer has a self--diagnostic func- While an error code appears in the display, all face- tion for the electrical system (except input power plate keypads are inoperable except the SELECT and water meter).
  • Page 21 Service Information Y S T continued from page 19 (↵) to start a recharge. As the EcoWater Systems conditioner enters the fill cycle of regeneration, re- Use the recharge keypad to manually advance the move the brinewell cover and, using a flashlight, ob- valve into each cycle and check correct switch op- serve fill water entering the tank.
  • Page 22: Wiring Schematic

    ECOWATER Service Information Y S T OTHER SERVICE WATER HAS SALTY TASTE 1. House water pressure low (adjust pump, if well system). HARD WATER BYPASS (hard water ‘‘bleeds’’ into 2. Partially restricted valve drain hose, top distributor, conditioned water supply). backwash flow plug, resin tank internal riser, or bottom 1.
  • Page 23: Dimensions/Specifications

    IN - - OUT 45--1/8” 36--9/16” 32” 32--1/2” MODEL NOMINAL RESIN TANK SIZE 8” DIA. X 35” 39.5” ECR 3000R20 10” DIA. X 35” 39.5” 44.8” ECR 3000R30, ECR 3002R30, ERR 3000R20 39.5” 10” DIA. X 47” 51.3” 56.6” ECR 3002R40, ERR 3002R30 12”...
  • Page 24 ECOWATER Dimensions/Specifications Y S T ECR 3000R30 ECR 3000R20 ERR 3000R20 ERR 3002R30 ECR 3002R40 ECR 3002R50S ECR 3002R70 ECR 3002R30 5,700 @ 1.1 6,700 @ 1.4 8,300 @ 1.6 8,100 @ 1.7 11,300 @ 2.2 23,000 @ 4.5 32,900 @ 6.2 Rated Softening Capacity 16,800 @ 4.3...
  • Page 25: Repair Parts

    ECOWATER Repair Parts Y S T ECOWATER SYSTEMS CONDITIONER ASSEMBLY...
  • Page 26 ECOWATER Repair Parts Y S T ECOWATER SYSTEMS CONDITIONER ASSEMBLY PART PART PART DESCRIPTION PART DESCRIPTION NUMBER NUMBER 7275907 Transformer, 24V ---10VA 7274210 Rim (Cabinet) 7288489 Remote Indicator (batteries not in- 7214244 Vapor Barrier cluded) 7273997 Salt Hole Cover 7218662...
  • Page 27 ECOWATER Repair Parts Y S T VALVE ASSEMBLY...
  • Page 28 Turbine Asm. (All models except below) 1148800 Fill Flow Plug, .3 7123061 Turbine Asm. (ERR 3002R30, 7269176 Noz., Ven. Asm. (ECR 3000R20 £) ¤ ECR 3002R40, ECR 3002R50S, 7091866 Nozz., Vent. Asm. (ERR 3000R20, ECR 3002R70) ECR 3000R30, ECR 3002R30, 7094898 Turb.
  • Page 29 ECOWATER Y S T EcoWater Systems PO Box 64420, St. Paul MN 55164--9888 1--800--86WATER...