Undersink reverse osmosis drinking water system (29 pages)
Summary of Contents for EcoWater ETF2300AIV10
Page 1
Models ETF2300AIV10 ETF2300AIV12 ETF2300EIV10 ETF2300EIV12 ETF2300AIV10 and ETF2300AIV12 are tested and certified by the Water Quality Association against NSF/ANSI Standard 372 for low lead content. ETF2300EIV10 and ETF2300EIV12 are tested and certified without media by the Water Quality Association against CSA B483.1, NSF/ANSI 61, and NSF/ANSI Standard 372 for low lead content.
Check local plumbing and electrical codes. The Changes or modifications not expressly approved by installation must conform to them. EcoWater Systems could void the user’s authority to Use only lead-free solder and flux for all sweat-solder operate the equipment. connections, as required by state and federal codes.
ECOWATER Specifications & Dimensions S Y S T E M S SPECIFICATIONS Model ETF2300AIV10 ETF2300AIV12 ETF2300EIV10 ETF2300EIV12 Model Code HAIV0 HAIV2 HEIV0 HEIV2 Amount of Zeolite Media 1.0 cu. ft. 2.0 cu. ft. – – Amount of Quartz Gravel 17 lbs.
Also inspect and note any dam- age to the shipping carton. Notify the transportation TOOLS, PIPE & FITTINGS, company if damage is present. EcoWater Systems is OTHER MATERIALS YOU WILL NEED not responsible for in-transit damages.
ECOWATER Media Loading (Models ETF2300EIV10 & ETF2300EIV12) S Y S T E M S MEDIA LOADING Riser Pipe Top Edge of Top Distributor Models ETF2300EIV10 & ETF2300EIV12, as manu- 0” to 1/2” factured, have no media other than quartz gravel at the bottom of the tank (See table on Page 3 for amounts).
ECOWATER Typical Installation Illustrations S Y S T E M S INSTALLATION USING ECOWATER BYPASS VALVE CROSS-OVER Use if water supply flows from the left. Filtered Include single or 3-valve bypass. Water OUT UNFILTERED FILTERED WATER Unfiltered WATER Water IN...
ECOWATER Installation S Y S T E M S 1. TURN OFF WATER SUPPLY Clip (2) a. Close the main water supply valve near the well 1” Copper Tube OUTLET pump or water meter. (install in filter valve or bypass valve) b.
Page 8
The included power supply converts 120V AC house- hold power to 24V DC. Plug the power supply into a a. Use the EcoWater ground clamp kit (not included) 120V, 60 Hz electrical outlet. Be sure the outlet is to make a jumper across the inlet and outlet pipes always “live”...
ECOWATER Description of Operation S Y S T E M S Service water enters the filter and passes through air tank of water, replacing it with air drawn through the captured at the top of the mineral tank. Dissolved iron aspirator.
“Connected” and gives you a key code. If not, you may need to cancel and use When the EcoWater Systems filter is plugged in for the the browser option. first time, a beep sounds and the display briefly shows a logo, followed by model information.
Page 11
14. Once the key code is displayed (it may take a few seconds) , write it down. It will be used when you 9. On your laptop, register your system on the EcoWater web site. tablet or phone, NOTE: If the “Connected” message shows “- - - - - -”...
Page 12
ECOWATER Setup Procedure S Y S T E M S continued from the previous page too long between writing down the key code and registering (an hour or less), the code may change. Iron (parts per million) No. of This is a security feature. Look up the new key People code, as described in the following note.
Page 13
In the verification screen, click the “logging in” link (or go to http://wifi.ecowater.com). EcoWater Wi-Fi web site. If a system is not shared, the dealer only has access to the “Dealer Communication 7. Log in with the e-mail and password that you entered Preferences”...
The filter status screens described in the previous sec- tion will not be displayed in a rolling sequence when During normal operation, the EcoWater Systems filter’s one of the following items is displayed: display shows up to four status screens. Page 19 Recharge status (Displayed during recharges, explains how individual screens can be turned on or off.
Page 15
ECOWATER Filter Operation S Y S T E M S MAIN MENU SETTING THE CURRENT TIME When the filter’s electronic control is first powered up, a “wizard” screen prompts you to set the current time Main menu (See Page 11). To change the time at a later date,...
Page 16
ECOWATER Filter Operation S Y S T E M S LOCKOUT FEATURE A “lockout” feature is available to prevent user modifica- When the lockout feature is on, the flashing padlock tion of parameters that affect filter performance. The icon will appear in any screen that would normally be unit is shipped from the factory with the lockout feature used to change a parameter in the list to the left.
Page 17
ECOWATER Filter Operation S Y S T E M S RECHARGING THE FILTER This feature may be used to assure an adequate supply 5. Press the SELECT ( ) button. If Recharge now is of conditioned water at times of unusually high water selected, the display immediately goes to the use.
Page 18
ECOWATER Filter Operation S Y S T E M S SETTING MAXIMUM DAYS BETWEEN RECHARGES When the filter’s electronic control is first powered up, a Iron (parts per million) No. of “wizard” screen prompts you to set the number of days...
Page 19
ECOWATER Filter Operation S Y S T E M S SETTING RECHARGE TIME MODIFYING ROLLING SCREENS When the filter’s electronic control is first powered up, During normal filter operation, up to four status screens the default time for starting an automatic recharge is are shown in sequence (See “Filter Status Screens”...
Page 20
ECOWATER Filter Operation S Y S T E M S SETTING THE LANGUAGE SETTING TIME FORMAT When the filter’s electronic control is first powered up, a Use this feature to select a 12-hour (AM/PM) or 24-hour “wizard” screen prompts you to set the language (See clock.
Page 21
ECOWATER Filter Operation S Y S T E M S SYSTEM INFORMATION Use these features to look up the following information about the filter Model information and its operations: Model information (model number and software version) Model: HAIV0 Wireless information FIG.
Page 22
ECOWATER Filter Operation S Y S T E M S CYCLE TIMES Use these features to change the following filter opera- tions: Backwash time Fast rinse time (aspirate time) To display these screens: 1. From any of the rolling status screens, press the SELECT ( ) button to display the Main menu.
Page 23
ECOWATER Filter Operation S Y S T E M S SPECIAL FEATURES Use these features to change the following operations: Auxiliary control (described on Page 24) Chemical feed volume** (described on Page 24) Chemical feed timer** (described on Page 24)
Page 24
For more details on the use of auxiliary controlled equipment in water treatment systems, consult the If the auxiliary control mode has been set to Chemical EcoWater Systems “Problem Water Guide.” feed, as described in the previous section, two addition- To select an auxiliary control mode: al lines (Chemical feed volume and Chemical feed 1.
ECOWATER Filter Operation S Y S T E M S DIAGNOSTICS This feature allows a service technician to check the 10. When finished viewing the Diagnostics screen, operating state of individual components in the filter press the SELECT ( ) button. The display will go (e.g.
ECOWATER Service Information S Y S T E M S CLEANING THE NOZZLE & VENTURI A clean nozzle & venturi (See Figure 90) is a necessi- O-ring Seal ty for the water filter to work properly. This small Screen Support...
Page 27
S Y S T E M S RELIEVING WATER PRESSURE WITH THE BYPASS VALVE(S) CAUTION: Always relieve water pressure in the EcoWater Systems filter, as described below, before removing parts from the valve or media tank. DE-PRESSURIZE 1. Put bypass valve(s) into Bypass position.
TROUBLESHOOTING - INITIAL CHECKS Always make these initial checks first: 5. Are inlet and outlet pipes connected to the EcoWater filter inlet and outlet respectively? 1. Is display blank? Check power source. 6. Is valve drain hose free of kinks and sharp bends, 2.
Page 29
ECOWATER Service Information S Y S T E M S AUTOMATIC ELECTRONIC DIAGNOSTICS CHECKING THE TURBINE 1. Display the Diagnostics screen, following the proce- This filter has a self-diagnostic function for the electrical dure on Page 25. system (except for input power and/or water meter).
ECOWATER Service Information S Y S T E M S TROUBLESHOOTING - OTHER SERVICE MANUAL ADVANCE RECHARGE CHECK Unfiltered Water Bypass (Unfiltered water “bleeds” into filtered water supply): Use the following procedures to advance the filter 1. Faulty inlet disc, seal or wave washer (See Pages through the recharge cycles to check operation.
ECOWATER Service Information S Y S T E M S SERVICE Valve Cam Position Switch FIG. 99 BACKWASH Valve Cam Position Switch FIG. 100 ASPIRATE Valve Cam Position Switch FIG. 101 ECOWATER Schematic S Y S T E M S...
(media not included with ETF2300EIV10 & ETF2300EIV12) 7124415 Gravel, 17 lbs. 7248706 Ground Clamp Kit Ù Not included with the filter. Ù To order parts, call your local EcoWater dealer or go to www.ecowater.com to locate a dealer in your area.
Page 34
ECOWATER Repair Parts S Y S T E M S VALVE EXPLODED VIEW Flow Plug Assembly Assembled View Wear Strip Seal Cross-section View...
Page 35
(2 req.) of Key Nos. 70 & 72) O-Ring, 1-1/16” x 1-5/16”, 7336410 Not included with filter. Ù pack of 20 To order parts, call your local EcoWater dealer or go to www.ecowater.com to locate a dealer in your area.
Should you need service, your local, independent EcoWater Dealer is only a phone call away. PHONE:____________________________________________________________ To obtain warranty service, notice must be given, within thirty (30) days of the discovery of the defect, to your local EcoWater Systems dealer.
Need help?
Do you have a question about the ETF2300AIV10 and is the answer not in the manual?
Questions and answers