Operating controls
Prog input
01
purpose of editing control and receiver functions.
P.E. Shunt
02
must not be removed otherwise the opener will not function correctly. Remove only when a P.E. beam is to
be connected.
Status LED
03
Datum Adjust Screw
04
Door Code
05
the door to open, stop or close.
Coding LED
06
pressed.
Set
button (orange) is used during the installation phase together with the Plus and Minus buttons to set
07
the door limit positions. The Set button is also used to re-initialise the Opener.
Operate
button (blue) is used during installation to test the open, stop and close cycles for the opener.
08
The opener has to be initialised by the Set button before the OPERATE button becomes operable.
Force Margin Set
09
The pressure can be adjusted manually using the Force Margin Set button (White). Pressing the force
margin set button and open or close button will increase or decrease the amount of force. The Force
Margin Set is only ever used if other environmental factors (wind, etc.) affect the operations of the door/
opener.
Plus
button (green - for limits setting and force margin) can be used during installation to set the open
10
limit position. Pressing this button will move the door in the open direction. Movement stops when the
button is released. NOTE: The open safety obstruction detection is inoperable whenever the Close Drive
button is used to move door. This button is disabled after initialisation. This button is also used to increase
the force margin sensitivity.
Open Limit LED
11
door is opening and remains steady on when the open limit position has been reached.
Minus
button (red - for limits setting and force margin) can be used during installation to set the close
12
limit position. Pressing this button will move the door in the close direction. Movement stops when the
button is released. NOTE: The close safety obstruction detection is inoperable whenever the Close Drive
button is used to move door. This button is disabled after initialisation. This button is also used to decrease
the force margin sensitivity.
Close Limit LED
13
is closing and remains steady on when the close limit position has been reached.
Engage/Disengagement Cord
14
power failure. The length of the string is also adjustable.
Security Lock for Manual Release
15
to disengage the opener into manual mode.
GDO-8v1 EasyRoller® II
8
is used for the connection of the Automatic Technology PG-3 Universal Programmer for the
The shunt has to be removed when connecting a Photo Electric (P.E.) Beam. NOTE: THE P.E. Shunt
(yellow) indicates when the datum adjustment screw has reached correct position.
Used to set mid-point of door travel during limits set up.
button (blue) is used for storing or erasing the transmitter button you wish to use to command
(red) light indicates whether a code is being stored or when a transmitter button is
The obstruction force pressure is set automatically by the opener during installation.
(green) theled is very helpful during installation. It illuminates and fl ashes when the
(red) the led is very helpful during installation. It illuminates and fl ashes when the door
is used to switch the door into manual mode especially in case of a
(where fi tted) prevents the manual release handle being pulled
Owner Installation Instructions
Need help?
Do you have a question about the GDO-8v1 EasyRoller II and is the answer not in the manual?
Questions and answers