Problem Solving; Troubleshooting - Crestron Isys TPS-4000 Operation Manual

10.4 inch tilt touchpanel
Hide thumbs Also See for Isys TPS-4000:
Table of Contents

Advertisement

10.4 Inch Tilt Touchpanel

Problem Solving

36 • 10.4 Inch Tilt Touchpanel: Crestron Isys

Troubleshooting

The table after this paragraph provides corrective action for possible trouble
situations. If further assistance is required, please contact a Crestron customer
service representative.
TPS-4000 Touchpanel Troubleshooting
TROUBLE
POSSIBLE CAUSE(S)
Touchpanel
Touchpanel is not
does not
communicating with the
function.
network.
Touchpanel is not
receiving network power.
Touchpanel is not
receiving power from a
Crestron power source.
Touchpanel is incorrectly
calibrated.
Touchpanel
Incorrect network wiring.
is not
responding.
Touchpanel Cresnet ID is
not set to match the Net
ID in the SIMPL program.
Touchpanel Cresnet ID is
not unique, two or more
units share the same ID.
Touchpanel
Standby timeout has
display is
elapsed.
dark.
Screen brightness is
improperly set.
Unexpected
Touchpanel is incorrectly
response
calibrated.
from the
touchpanel.
Touchpanel
Incorrect RS-232 settings.
does not
communicate
with RS-232
devices.
®
TPS-4000
®
Crestron Isys
TPS-4000
CORRECTIVE ACTION
Use Viewport (via SIMPL
Windows or VT Pro-e) to poll the
network. Verify network
connection to the touchpanel.
Confirm that power is supplied to
the network.
Use a Crestron control system or
an approved Crestron power
supply.
Enter "SETUP MODE" or use
Viewport to Put Touchpanel Into
Calibrate Mode and recalibrate.
Touch the screen to remove the
message and verify correct wiring
to all connectors.
Touch the screen to remove the
message and enter Performance
Viewport (via SIMPL Windows or
VT Pro-e) to poll the network.
Verify that the Cresnet ID for the
touchpanel is properly set to
match the Net ID in the SIMPL
program.
Enter Performance Viewport (via
SIMPL Windows or VT Pro-e) to
poll the network and verify that
each ID is used only once.
Touch the screen to reactivate.
Enter "SETUP MODE" and alter
screen brightness from the setup
menu.
Enter "SETUP MODE" or use
Viewport to Put Touchpanel Into
Calibrate Mode and recalibrate.
Match communication settings of
touchpanel to peripheral device.
Operations Guide - DOC. 6268

Advertisement

Table of Contents
loading