4. Enter a command that chooses one of the RS-232 communication
options. Use the same spelling as shown in the last touchpanel
response.
5. The TPS-4000 responds with the following:
New RS232mode set. Reboot to take effect.
6. Enter the following command:
reboot
7. The TPS-4000 responds with the following:
Rebooting system. Please wait.
8. From the Viewport, select Remote | Remote Console | Disconnect.
At this point, the PC and the TPS-4000 are no longer communicating. Assuming that
the touchpanel is properly connected for use (as shown in the diagram for
"Communication Settings" on page 28) and the control system is connected to the
PC, the setup screens can be displayed to set the Net ID and other configurations.
NOTE: Alternatively, use a Cresnet command from the Viewport (communicating
to the control system) to access the setup screens. Verify the Net ID of the TPS-4000
and select Functions | Put Touch Panel into Setup Mode. Enter the Net ID and
click OK.
10.4 Inch Tilt Touchpanel: Crestron Isys