Download Print this page

Emerson Rosemount 3144P Quick Start Manual page 20

Temperature transmitters with foundation fieldbus protocol
Hide thumbs Also See for Rosemount 3144P:

Advertisement

Quick Start Guide
5.5
International
5.5.1
E7 IECEx Flameproof
Certificate IECEx FMG 12.0022X
Standards IEC 60079-0:2011, IEC 60079-1:2014-06
Markings
Specific Conditions of Use (X):
1. See certificate for ambient temperature range.
2. The non-metallic label may store an electrostatic charge and become
a source of ignition in Group III environments.
3. Guard the LCD display cover against impact energies greater than
four joules.
4. Flameproof joints are not intended for repair.
5. A suitable certified Ex d or Ex tb enclosure is required to be connected
to temperature probes with Enclosure option "N".
6. Care shall be taken by the end user to ensure that the external
surface temperature on the equipment and the neck of DIN Style
Sensor probe does not exceed 266 °F (130 °C).
7. Non-standard paint options may cause risk of electrostatic discharge.
Avoid installations that cause electrostatic build-up on painted
surfaces and only clean the painted surfaces with a damp cloth. If
paint is ordered through a special option code, contact the
manufacturer for more information.
Additionally available with option K7
IECEx Dust
Certificate IECEx FMG 12.0022X
Standards
Markings
Specific conditions of use (X):
1. See certificate for ambient temperature range.
20
Ex db IIC T6...T1 Gb, T6(-50 °C ≤ T
T
≤ +60 °C)
a
See
Process temperature limits
IEC 60079-0:2011 and IEC 60079-31:2013
Ex tb IIIC T130 °C Db, (-40 °C ≤ T
See
Process temperature limits
≤ +40 °C), T5...T1(-50 °C ≤
a
for process temperatures.
≤ +70 °C); IP66
a
for process temperatures.
Rosemount 3144P
March 2020

Advertisement

loading