Garbled Terminal Display - H3C S6520XE-HI Series Installation Manual

Table of Contents

Advertisement

Solution
To resolve the issue:
Verify that the power module is supplying power to the switch.
1.
Verify that the console cable is correctly connected.
2.
Verify that the console cable does not have any problems and the terminal settings are correct.
3.
If the issue persists, contact H3C Support.
4.

Garbled terminal display

Symptom
Terminal display is garbled.
Solution
To resolve the issue:
Verify that the following settings are configured for the terminal:
1.
Baud rate—9,600.
Data bits—8.
Parity—none.
Stop bits—1.
Flow control—none.
If the issue persists, contact H3C Support.
2.
31