Verify
Error
Success
6.1.2
Procedure via Buttons and LEDs
The following steps must be followed in order for the Cyclone PRO to operate
properly after the Cyclone PRO has been configured:
When the "Success" LED lights up, you have successfully programmed your
target.
6.1.3
Example
When the Cyclone PRO is powered up, the Standby LED is turned on. After
the user programs the contents and procedures into the Cyclone PRO on-
board flash, the Cyclone PRO may be used as a Stand-Alone Programmer.
Suppose the user wants to perform the following instructions for a 68HC908
target:
1) Erase Module
Cyclone PRO User Manual
1. Turn off the target power supply if the "POWER IN" Jack is adopted.
2. Turn off the Cyclone PRO board power.
3. Set the correct Jumper settings.
4. Connect the target power supply to the "POWER IN" Jack, if applica-
ble.
5. Connect the "POWER OUT" Jack to the target board power, if appli-
cable.
6. Connect the MON08 Header Ribbon Cable to the target MON08 port,
or the BDM Header Ribbon Cable to the target BDM port.
7. Turn on the Cyclone PRO board power.
8. Turn on the target power supply, if applicable.
9. Press the "START" push button on the Cyclone PRO. You will see the
LEDs light up as specific functions are being executed.
EEPROM.
The Cyclone PRO is verifying that the contents
programmed.
The Cyclone PRO failed to execute the functions as
instructed.
The Cyclone PRO executed the functions
successfully.
CYCLONE PRO