B.1 MEMORY MAPPING
Table B–4: MODBUS MEMORY MAP: SETPOINTS
Register
DDE Item Name
Address
(Mnemonic)
R43945I
G3_TRIPMODE
R43946I
G3_CARRSTART
B
R43947I
G3_WKINFTRIP
R43948I
G3_TL1PICKUP
R43949I
G3_TL4PICKUP
R43950I
G3_TL4DROPOUT
R43951I
G3_TL5PICKUP
R43952I
G3_TL5DROPOUT
R43953I
G3_TL6PICKUP
R43954I
G3_TL6DROPOUT
R43955I
G3_TL16PICKUP
R43956I
G3_TL24DROPOUT
R43957I
G3_TL25DROPOUT
R43958I
G3_TL26PICKUP
R43959I
G3_POSSEQANG
R43960I
G3_ZERSEQANG
R43961F
G3_ZLINE
R43963F
G3_ZEROSEQK0
R43965F
G3_LINELENGTH
R43967I
G3_LINEUNIT
R43968I
G3_CTRATIO
R43969I
G3_PTRATIO
R43970F
G3_FLTLOCK
R43972I
G3_FLTRESET
R43973I
G3_MOBZONE
R43974I
G3_MOBCHARANG
R43975I
G3_BLOCKWHAT
R43976I
G3_BLOCKZ1
R43977I
G3_BLOCKZ2
R43978I
G3_BLOCKZ3
R43979I
G3_BLOCKZ4
R43980I
G3_USE_OST
R43981I
G3_NUMBRCHAR
R43982I
G3_TRIPIN_OUT
R43983F
G3_FWDREACH
B-
22
(Sheet 18 of 27)
Contents
Units/Value/Range
TRIPMODE
0 = 3POLE; 1 = 1POLE;
2 = 1POLEZ2
CARRSTART
0 = DIR; 1 = IPB; 2 = FD
WKINFTRIP
0 = No; 1= Yes
TL1PICKUP
1 to 200 msec. step 1
TL4PICKUP
0 to 50 msec. step 1
TL4DROPOUT
0 to 50 msec. step 1
TL5PICKUP
0 to 200 msec. step 1
TL5DROPOUT
0 to 200 msec. step 1
TL6PICKUP
0 to 200 msec. step 1
TL6DROPOUT
0 to 200 msec. step 1
TL16PICKUP
8 to 99 msec. step 1
TL24DROPOUT
30 to 500 msec. step 1
TL25DROPOUT
30 to 500 msec. step 1
TL26PICKUP
0 to 50 msec. step 1
POSSEQANG
25 to 90° step 1
ZERSEQANG
25 to 90° step 1
0.01 to 50 Ω step 0.01
ZLINE
0.05 to 250 Ω step 0.05
G3_ZEROSEQK0
1.0 to 7.0 step 0.1
LINELENGTH
0.0 to 500.0 step 0.1
LINEUNIT
0 = Miles, 1 = Km
CTRATIO
1 to 5000 step 1
PTRATIO
1 to 7000 step 1
FLTLOCK
0 to 99.9 sec. step 0.1
FLTRESET
0 to 999 minutes step 1
MOBZONE
0 = Zone 2; 1 = Zone 3;
2 = Zone 4
MOBCHARANG
30 to 130° step 1
BLOCKWHAT
0 = BLKALL; 1 = BLKDIST;
2 = BLKPHAS; 3 = BLKNONE
BLOCKZ1
0 = No; 1 = Yes
BLOCKZ2
0 = No; 1 = Yes
BLOCKZ3
0 = No; 1 = Yes
BLOCKZ4
0 = No; 1 = Yes
USE_OST
0 = No; 1 = Yes
NUMBRCHAR
2, 3
TRIPIN_OUT
0 = IN; 1 = OUT
0.1 to 75.0 Ω step 0.1 (5A)
FWDREACH
0.5 to 375.0 Ω step 0.5 (1A)
LPS-D Line Protection System
APPENDIX B
R/W
Format
Code
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
Float
R/W
Float
R/W
Float
R/W
INT
R/W
INT
R/W
INT
R/W
Float
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
Float