HBM T40B Mounting Instructions page 24

Hide thumbs Also See for T40B:
Table of Contents

Advertisement

Available languages

Available languages

Mechanical installation
Important
Use a threadlocker (medium strength, e.g. LOCTITE) to glue the screws into
the counter thread to exclude prestressing loss due to screw slackening, in the
event of alternating loads.
Notice
Comply with the minimum thread reach as per table 5.1. The maximum thread
reach must be selected so that the counter flange is not touched. Otherwise
significant measurement errors may result from a torque shunt, or the trans­
ducer may be damaged.
Measuring
range
NVm
50
100
200
500
1 k
2 k
3 k
5 k
10 k
1)
DIN EN ISO 4762; black/oiled/m
2)
d = screw diameter in mm
Tab. 5.1
Fastening screws
22
Fastening screws
1)
Z
Property class
M8
M8
M8
M10
M10
M12
M12
M14
M16
= 0.125
tot
A03452_15_X00_00 HBM: public
Prescribed
tightening
moment
10.9
10.9
10.9
10.9
10.9
10.9
12.9
12.9
12.9
Minimum
thread reach
NVm
34
34
34
67
67
1.2 x d
115
135
220
340
mm
2)
T40B