ICS ELECTRONICS 4863 Manual page 96

Table of Contents

Advertisement

TABLE 3-3
Keyword
INITiate
[:IMMediate]
:CONTinuous
ABORt
CALibrate
:IDN <string>
ICS Electronics
:DATe <date>
:DATe?
DEFault
:LOCK
(1)
Notes -
Setting changes are immediate after command execution.
Provide 15 msec. delay for internal reconfiguration.
(2)
Setting other than the default value are not saved permanently.
SCPI COMMANDS AND QUERIES
(CONTINUED)
Default
Value
Starts Trigger branch
Enables a single trigger operation
OFF
Enables ongoing external triggers. Values
= 0|1 or OFF|ON.
Disables trigger function
Starts calibrate branch
Sets user IDN message. String is up to 72
characters and consists of four fields (manu-
facturer, model code, serial number and
firmware revision) separated by commas.
e.g. ICS Electronics,4863, S/N 012345,
Rev 0.6 (05-19-06).
00/00/0000
Saves IDN message and date.
operation lights all the LEDs. Date is in
mm/dd/yy format.
Queries the calibration date. The response
is 00/00/0000 for factory default settings.
Sets Flash to factory settings.
0
Disables configuration commands when On.
Values = 0|1 or OFF|ON. Tables 1-4 and 1-
5 list the locked commands.
3-29