Figure 2-11 Cleveland Range Single Water Supply Arrangement when Using
f)
A 40 or 50-mesh water strainer (dirt filter)
of one of the types and construction
illustrated in Figure 2-12, Cleveland
Range part number 106684 or 19870 is
supplied with the unit and should be
installed where indicated in the plumbing
layout. Note: On some Models the
strainer has already been installed as
part of the internal water piping.
·
Make sure the arrow on the strainer
body points in the direction of flow
into the steamer.
·
Install the strainer so the access nut
points down.
g) Construct all supply lines up to the point of installing the strainer. Flush the water supply
lines before connecting the strainer.
h) Apply pipe dope or Teflon tape to any threaded connection.
d. Testing Water Supply Lines
1). Check all connections for proper tightness. Remove the side panel to inspect water connections
inside the steamer.
2). Open the water supply valves.
3). Check all lines and connections for leakage, both inside and outside the steamer.
4). If Startup and Checkout will be performed next, leave the right side panel off; otherwise, replace
the side panel and secure it to the unit.
C. STARTUP AND CHECKOUT
The Startup and Checkout procedure prepares a recently installed or repaired steamer for operation. The
procedures check proper electrical, gas, water, and drain connections to the steamer, and verify basic
steamer operation.
Water Connection D on
Dimension Diagram
Water Connection E on
Dimension Diagram
Separate Conditioned Feed Water Supply
*
(
May be installed internal to the steamer on some models)
Check Valve
*
Strainer
Pressure Reducer
(if required)
P/N 106684
Figure 2-12 Water Strainer Assembly
16
Air/Water Column
(if required)
Standard Cold
Water Supply
Main Water
Shut Off Valve
Conditioned Cold
Water Supply
P/N 19870
Flow
Flow