PROBLEM
Power indicator light
does not turn on when
ON/OFF lever/switch is in
the ON position.
Power
indicator
light
does not turn ON when
ON/OFF lever is in the
ON position.
Power ON and steam
generator does not fill.
Control panel POWER
indicator light ON and
steamer does not make
any steam in manual or
timed modes.
Abnormal amount of
steam coming from drain.
Reduced steam flow into
cooking compartment.
Power light is ON, but
timer
does
not
light.
(Electronic Timer Models
only)
Table 3-1 Trouble Shooting Guide
POSSIBLE CAUSE
Power turned OFF at main power
switch.
ON/OFF lever/switch not fully turned
to the ON position.
Inoperative controls or failed light.
Power turned OFF at main power
switch.
ON/OFF lever/switch not fully turned
to the ON position
Inoperative controls or failed light.
Water supply to steamer shut off.
Water line strainer and/or external
filter system is clogged
Inoperative Solenoids or controls.
Water supply to steamer shut OFF.
Door interlock switch not engaged or
has failed.
Hi-limit switch has tripped.
Water line strainer is clogged.
Gas supply valve is closed.
Steamers gas valve is closed.
Inoperative controls or solenoid.
Hot water instead of cold water
connected to condenser fitting.
Water supply to condenser turned
OFF.
Condenser water line strainer and/or
nozzle is clogged.
Water supply line to the condenser
blocked, broken, or leaking.
Inoperative controls, thermostat or
solenoids.
Steam generator scale buildup
Gas inlet pressure is low.
Inoperative or improperly adjusted
controls
Timer transformer has failed
Inoperative controls
(Continued on next page)
Turn ON power at main power switch.
Turn lever/switch to the full ON position.
See note #1
Turn on power at main power switch.
Turn lever/switch to the full ON position.
See note # 1.
Open water supply valves.
Clean water supply strainer and/or filter
system.
See note # 1.
Open water supply valves.
Close door completely. If problem
persists see note #1.
Reset Hi-limit, if condition persists, see
note #1.
Clean water supply strainer.
Turn OFF unit and open gas supply
valve
Turn gas valves to open position.
See note # 1.
Make proper connections. See section
on Water Supply
Open water supply valve.
Clean out condenser water supply
strainer and/or nozzle.
Repair or replace water supply line. See
note # 1.
Turn OFF electricity at main external
power switch. See note # 1.
Descale steam generator with Cleveland
Range approved descaler.
The unit requires a minimum inlet
pressure of 4.5 inches W.C. to operate.
See note #2.
See note #1.
See note #1
See note #1
25
REMEDY/REFERENCE