Chapter 2 Installation Instructions; General; Installation Of The Steamer - Cleveland 24CGA10.2 Installation And Maintenance Instructions Manual

Dual gas steam generator & convection steamer
Hide thumbs Also See for 24CGA10.2:
Table of Contents

Advertisement

CHAPTER 2 INSTALLATION INSTRUCTIONS

A. GENERAL
This equipment should only be installed by qualified, professional plumbers, pipe fitters, and electricians.
·
The installation of this steamer must conform with the Basic Plumbing Code of the Building Officials and
Code Administrators International, Inc. (BOCA), the National Fuel Gas Code, ANSI Z223.1-(latest
edition) or the Natural Gas Installation Code CAN/CGA-B149.1 or the Propane Installation Code
CAN/CGA-B149.2 as applicable, The National Electrical Code, ANSI/NFPA No. 70-(latest edition) or the
Canadian Electrical Code, CSA C22.2 as applicable, the Food Service Sanitation Manual of the Food
and Drug Administration (FDA) and all applicable state and local codes and regulations.
·
The installation instructions must be read in their entirety before starting the installation of this steamer.
DEATH, INJURY, AND EQUIPMENT DAMAGE could result from the
improper installation, adjustment, alteration, service or maintenance
of a steamer or installation of a unit damaged during shipment or
storage. Any of these conditions could also void the equipment
warranty.
DO NOT INSTALL a Gemini steamer that has been damaged.
Install the Gemini steamer according to the policies and procedures
outlined in this manual.
·
To install this steamer, the following requirements must be considered when selecting a location.
a. A suitable drain must be available within 12 ft. of the steamer.
b. An electrical supply matching the power requirements found on the rating plate must be available.
c. A gas supply matching the fuel requirements found on the rating plate must be available.
d. The location must have sufficient space to meet the clearance requirements of the steamer as
outlined in Chapter 2, Section B, Part 1, "Locating the Steamer".
e. A water supply meeting the requirements outlined in Chapter 2, Section B, Part 6 "Water Supply
Requirements and Installation" must be available.
B. INSTALLATION OF THE STEAMER
After selecting the steamer's operating location the steamer can be positioned, and installed. After Final
Setup and Checkout, the Gemini steamer should provide years of reliable operation.
WARNING
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gemini 24cga6.2Gemini 24cga10.2

Table of Contents