Cleveland 24CGA10.2 Installation And Maintenance Instructions Manual page 10

Dual gas steam generator & convection steamer
Hide thumbs Also See for 24CGA10.2:
Table of Contents

Advertisement

GAS
1-1/4" IPS line size, 3/4" connection
NATURAL
PROPANE
Piping 3/4" N.P.T
Piping 3/4" N.P.T.
Supply pressure
Supply pressure
4.50" W.C. Min.
11.00" W.C. Min.
14.00" W.C. Max.
14.00" W.C. Max.
Manufacturer must be notified if unit will
be used above 2,000 feet
Figure 2-2 Gemini 24CGA10.2 Dimensions and Clearances
OPERATING
CLEARANCE
SECONDARY
CLEARANCE
ELECTRIC
120V-1Phase, 60 Hz.
BTU
2 Fans & controls
72,000
150 watts each
each
Generator
144,000 total
COLD WATER
35 PSI minimum
RIGHT = 12.00" for service 1-1/2" dia.
60 psi maximum
SIDES = 3.00"
(1) 1/4" dia. IPS for
REAR = 3.00"
Generator
(1) 1/4" dia. IPS for
FRONT = 24.00"
Condenser
7
CLEARANCE
DRAINAGE
Do not connect other
units to this drain
Drain must be vented
Do not use PVC pipe