After a few minutes steam begins to enter the compartment from the nozzles. A small
quantity of water may drip from the nozzles until steam clears the lines.
·
After a few more minutes the compartment will reach cooking. The thermostat will close
temperature (the pause light will go OFF for mechanical timer units) and the condenser
solenoid clicks open and condenser flow starts. After a few seconds, a stream of water
flows from the drainpipe. If no drain water flows, check that the water supply valves are
open, and the lines are connected properly.
·
With the unit in manual cooking mode the unit should steam continuously until turned OFF,
or set to the timed cooking mode. After several minutes of steaming, check for steam leaks
around the door gasket.
6). As the unit continues to steam in Manual Cooking Mode, test the no-water/low water safety
circuit.
a) Close the steamers manual water supply valve. Observe the steam generator probe
cylinders while steaming continues.
b) As water steams out of the generator, the water level drops below the low water safety
cutoff point. The steamer should automatically shutoff.
c) Re-open the manual water supply valve. The steamer's controls automatically refill the
steam generators with water to the safety level and resumes steaming.
7). When the TIMED/MANUAL switch is set to TIMED (and the timer is zeroed), the steam
generating cycle stops. Press the TIMED end of the TIMED/MANUAL switch for both
compartments.
·
The main burners turn OFF, and the condenser flow stops. On DIAL timer models only
the buzzer will sound for 3 seconds.
·
Steam stops entering the cooking compartment.
8). Open the cooking compartment door to vent the steam and allow the compartment to cool
slightly. After 2 or 3 minutes, close the door and continue testing.
9). With the TIMED/MANUAL switches set to TIMED, set the timers of both compartments for 10
minutes.
10). When the START/STOP key is pressed [Keypad Models] or as soon as the dial is set [Dial
timer Models], the steam generating cycle starts. This is the same sequence observed in steps
5 and 7, except:
·
The timer controls the cycle.
·
The elapsed time to produce steam is shorter because the water in the steam generator
and the cooking compartment were preheated during step 5.
·
The timer automatically starts the step 7 functions after counting down to zero.
11). After the timed operation has been started, observe the following steam generating functions.
a) KEYPAD CONTROL
The timer display changes to PAUS until the cooking compartment reaches cooking
temperature. When it does, the timer begins counting down to zero.
DIAL TIMER CONTROL
The Pause light comes ON until the cooking compartment reaches cooking temperature.
When it does, the timer begins counting down to zero, and the Pause light turns OFF.
b) When the unit reaches temperature the condenser solenoid clicks open and condenser flow
starts. A small stream of water flows from the drainpipe.
22