Cleveland 24CGA10.2 Installation And Maintenance Instructions Manual page 9

Dual gas steam generator & convection steamer
Hide thumbs Also See for 24CGA10.2:
Table of Contents

Advertisement

GAS
1-1/4" IPS line size, 3/4" connection
NATURAL
PROPANE
Piping 3/4" N.P.T Piping 3/4" N.P.T.
Supply pressure
Supply pressure
4.50" W.C. Min.
11.00" W.C. Min.
14.00" W.C. Max.
14.00" W.C. Max.
Manufacturer must be notified if unit will
be used above 2,000 feet
OPERATING
CLEARANCE
SECONDARY
CLEARANCE
ELECTRIC
120V-1Phase, 60 Hz.
BTU
2 Fans & controls
50,000
150 watts each
each
Generator
100,000 total
Figure 2-1 Gemini 24CGA6.2 Dimensions and Clearances
COLD WATER
35 PSI minimum
RIGHT = 12.00" for service 1-1/2" dia.
60 psi maximum
SIDES = 3.00"
(1) 3/8" dia. IPS for
REAR = 3.00"
Generator
(1) 3/8" dia. IPS for
FRONT = 24.00"
Condenser
6
CLEARANCE
DRAINAGE
Do not connect other
units to this drain
Drain must be vented
Do not use PVC pipe