8] SETTINGS

Door station address settings
Bit State
Default setting, ID = 0(00), set to the first
Door Station.
ID = 1(10), set to the second Door
Station.
ID = 2(01), set to the third Door Station.
ID = 3(11), set to the fourth Door Station.
Switch language voice
Set bit 6 to ON or connect power and within 10 secs, press and hold KEY_CALL to enter
the settings mode.
Press KEY_CALL to switch
language voice prompt mode
LED_UNLOCK: ON
LED_KEY: ON
Buzzer --> No language voice
Note: If no operations are completed for 10 seconds, the panel will exit the settings
mode automatically.
2EASY 2-wire 1-button Video Door Station
2 bits on the DIP switches can be configured. The switches
can be modified either before or after installation.
Description
Press KEY_CALL to switch
language voice prompt mode
LED_UNLOCK: ON
LED_KEY: ON
Buzzer --> Language voice 1
CDV-91S
Unlock time settings
Bit State
Default setting, unlock time is Xs
Set the unlock time to 3s
Set the unlock time to 5s
Set the unlock time to 10s
...
Description
Press KEY_CALL to switch
language voice prompt mode
LED_UNLOCK:ON
LED_KEY:ON
Buzzer --> Language voice X