CDVI 2EASY CDV-91S Manual page 5

2-wire 1-button video door station
Table of Contents

Advertisement

EN
Electric lock connections
Door lock controlled with internal power
Notes:
1. This mode only supports Fail Secure (power
on to unlock) Strikes
2. The door lock is limited to 12V, and holding
current must be less than 250mA.
3. The door lock control is not timed from Exit
Button (EB).
4. The monitor's Unlock Mode parameter must
be set to 0 (by default).
Door lock controlled with dry contact
Notes:
1. An external power supply must be used
according to the lock power requirements.
2. The internal relay contact is restricted to AC
or DC Max 24V/1A
3. Remove jumper before connecting.
4. Setup the monitor's Unlock Mode for
different lock types.
• Power-on-to-unlock (fail secure): Unlock
Mode = 0 (default)
• Power-off-to-unlock (fail safe): Unlock Mode
= 1
2EASY 2-wire 1-button Video Door Station
CDV-91S
5