3.1 Maintenance Items
3.1.2

Lubrication of the LM Guide

Using a grease gun, lubricate the metal grease to the specified
points once a year, following the procedures below.
• Recommended Grease: AFC grease by THK.
• Grease Gun: MG70
• Grease Gun Discharge Rate; app. 0.6ml / stroke
I m p o r t a n t
Never apply a grease to the steel belt.
Doing so may cause a malfunction in sub-
scanning.
1.
Remove the rear cover.
p.28")
2.
Lubricate via grease nipple "A" on the balance weight.
Trigger the grease gun twice.
3.
Move the balance weight up and down until the two grease
nipples [B] can be seen through the lubrication hole, and
then lubricate via these two points.
4.
Lubricate via grease nipple "B" (2 locations).
Trigger the grease gun twice for each nipple.
Checks after lubrication
Expose the solid density image, and check there is no horizon-
tal streaks on the image.
I m po r t a n t
If rust is found when lubricating, never
fail to wipe it off.
94