2.7 Electrical Unit
2.7.5
Replacement of PSB (±15V supply)
1.
Remove the rear cover.
p.28")
2.
Unplug two connectors from PSB (±15V supply).
JP6, JP7
3.
Remove a fixing screw, and pull out the PSB from board's
support legs (3pcs).
4.
Carry out reassembly in the reverse order to that described
above.
Remarks for installation
When it is replaced with a new PSB, check the voltage at the
following point is +15V and -15V using a digital multi meter.
+15V: PCB JP7 / PIN1 (+15V) - PIN2 (GND)
-15V: PCB JP7 / PIN3 (-15V) - PIN2 (GND)
("2.2.1 Removal of the Rear Cover,
REGIUS MODEL 190 Service Manual Ver.1.00 2004.11.01
PSB (+/-15V supply)