  • Page 1 DIRECT DIGITIZER REGIUS MODEL 190 (DD-941) OPERATION MANUAL CODE NO. : 0676 No. 26-2, Nishishinjuku 1-chome, Shinjuku-ku, Tokyo 163-0512, Japan...
  • Page 2: Table Of Contents

    Table of Contents Foreword ……………………………………………………………………… 1 About this Manual …………………………………………………………… 3 Ch.1 Safety Precautions & Warnings……………………………………… 7 Ch.2 Product Outline ……………………………………………………… 19 Name of Parts ……………………………………………………………… 20 Operation Flow ……………………………………………………………… 23 Ch.3 Operation ……………………………………………………………… 25 Handling the Cassette ……………………………………………………… 26 Power ON ……………………………………………………………………...
  • Page 3: Foreword

    Foreword We thank you for purchasing the "Direct Digitizer DD-941" (henceforth referred REGIUS CONSOLE CS-1 to as REGIUS MODEL 190). REGIUS CONSOLE CS-3 This console (controller) The REGIUS MODEL 190 is designed to read REGIUS Plates. controls communication, The basic operational procedures for the REGIUS MODEL 190 such as start processing, and output of the image data read by the up/shut down, patient registration and parameter settings, are carried out using...
  • Page 4 (3) Should any discrepancies, errors or omissions be discovered, KONICA MINOLTA should be contacted. (4) Notwithstanding item(3) above, KONICA MINOLTA shall accept no responsibility of any claims made against loss or loss of profits arising from use of the product.
  • Page 5: About This Manual

    About this Manual Be sure to read this section before using this manual. REGIUS MODEL 190 OPERATION MANUAL Ver.1.04 2004.12...
  • Page 6 How to use this manual This manual consists of the chapters listed below. Chapter1 Safety Precautions & Warnings This chapter details warnings and cautions for operation of the REGIUS MODEL 190. Chapter2 Product Outline This chapter gives an outline of the REGIUS MODEL 190. Chapter3 Operation This chapter details the procedures for operation of the REGIUS...
  • Page 7 Page Layout Title This title stands for the general meanings for the descriptions. Power ON The following is a description of the procedure for switching on the REGIUS MODEL 190. Start and shut down of the REGIUS MODEL 190 are carried out from the REGIUS Console CS-1/CS- 2/CS-3 that controls it.
  • Page 8 REGIUS MODEL 190 OPERATION MANUAL Ver.1.03 2004.12...
  • Page 9: 1 Safety Precautions & Warnings

    Safety Precautions & When using the REGIUS MODEL 190, the cautions detailed in this chapter must be strictly Warnings followed in order to correctly use the device. REGIUS MODEL 190 OPERATION MANUAL Ver.1.03 2004.12...
  • Page 10 Alert and Symbol Marks Safety Alert Symbol This is the safety alert symbol and is intended to draw the attention of the user to potential dangers to the user him/herself or to others that may arise during the use or operation of this system. These messages must be read thoroughly and strictly observed.
  • Page 11 Warning Text (Signal Word) Signal words indicate the degree of potential hazards in the product. There are three degrees of caution labels, and each is used depending on the level of risk and damage caused by incorrect use and mishandling. DANGER :Failure to observe the caution will produce high risk of serious or fatal injury.
  • Page 12 Types and Locations of Warning Labels Warning labels on the REGIUS MODEL 190 are affixed at the locations shown below. Top side Do not remove these warning labels from the unit. CAUTION NEVER shake or move the device. Doing so may cause the monitor to drop or result in monitor damage.
  • Page 13 Figure illustrating unit with front door opened Shelf on the inside of the front door Do not place any object on the shelf. Interior of the Main Unit CAUTION The temperature of the elevator section may reach 60 . Do not touch hot surface. HIGHT TEMPERATURE Transport Unit...
  • Page 14 Overall Cautions When using the REGIUS MODEL 190, the cautions detailed below must be strictly observed and correct handling procedures followed at all times. This operation manual should be read thoroughly in order to fully understand the REGIUS MODEL 190. WARNING Both lasers and high voltage are used in the REGIUS MODEL 190.
  • Page 15 Cautions Relating to the Power Supply and the Power Cable WARNING ● Never hold the power plug with wet hands. Never plug in or remove the power plug from the power socket with wet hands: there is a risk of electrocution. ●...
  • Page 16 ● Do not use an Ethernet cable other than the one specified. The ethernet cable supplied with the unit or, alternatively, an ethernet cable specified by Konica Minolta Medical & Graphic, inc., should be used; all devices and connectors used with the cable should be carefully checked before proceeding with connection.
  • Page 17 Cautions to be Observed During Usage WARNING ● Do not touch the unit when thunder is heard. In the event of a thunderstorm, the power plug should be immediately disconnected from the power outlet. Additionally, if thunder is heard while the power cable is still connected, do not touch either the unit itself or any of the cables: doing so may result in electrocution.
  • Page 18 Cautions Regarding Care and Maintenance of the Unit WARNING ● Do not attempt to disassemble or to carry out repairs or modification to the unit. Under no circumstances should the user attempt to disassemble or to carry out any repairs or modifications to the unit. Any attempts to do so may result in malfunctioning of the unit and produce the risk of electrocution or fire.
  • Page 19 Cautions Relating to Handling and Storing Cassettes WARNING Cautions relating to the fluorescent medium of the REGIUS Plate. When the REGIUS Plate is damaged causing the fluorescent substance to be exposed to the open air, following cautions should be noted. ●...
  • Page 20 p.26 Handling the Cassette CAUTION Cautions relating to Usage of the Cassette ● To prevent possible injury, be careful not to drop the cassette during usage. Dropping the cassette on the foot may cause injury. ● Be careful not to pinch your fingers when opening/closing the cassette lid.
  • Page 21: 2 Product Outline

    Product Outline This chapter details an outline of the REGIUS MODEL 190. REGIUS MODEL 190 OPERATION MANUAL Ver.1.03 2004.12...
  • Page 22: Name Of Parts

    Name of Parts Part names and corresponding functions are detailed below. Front Side LCD Panel "operation" Button Errors and operational status are Depressing this button turns the unit ON or OFF. Depressing the button ON will displayed on the LCD panel. start initialization of the unit.
  • Page 23 Rear Side Exhaust Outlet To prevent temperature increase inside the device, cleaning should be carried out regularly following procedures described in Chapter. 5 "Care & Ethernet Port Maintenance." p. 57 Insert the Ethernet cable into this port to Care&Maintenance connect the reader to the CS-1/CS-2/CS-3 or network.
  • Page 24 Internal Cassette Magnetizing Plate Magnetically attaches the cassette. Transport Unit Transports the cassette to the image reading position. Handle Holder Return the handle to this handle holder. REGIUS MODEL 190 is designed so that the front door cannot be closed unless the handle is returned to its correct position.
  • Page 25: Operation Flow

    Operation Flow The sequence of transportation of the cassette within the REGIUS MODEL 190 is shown below. Front panel of the Cassette is inserted Cassette is transferred cassette is removed Front panel of the cassette Image is erased Optical unit reads is replaced by the erasing lamp the plate...
  • Page 26 REGIUS MODEL 190 OPERATION MANUAL Ver.1.03 2004.12...
  • Page 27: 3 Operation

    Operation This chapter details the procedure for operation of the REGIUS MODEL 190. REGIUS MODEL 190 OPERATION MANUAL Ver.1.03 2004.12...
  • Page 28: Handling The Cassette

    Handling the Cassette The following is a description for handling the cassette. Before handling the cassette, "Cautions Relating to Handling and Storing Cassettes" detailed on p.17 should be thoroughly read and precautions detailed therein carefully followed. p.17 Cautions Relating to Handling and Storing Cassettes Name of Parts Size Classification Seal...
  • Page 29 Cassette Structure REGIUS Plate Back Panel of Cassette Records the X-ray image. REGIUS Plate A REGIUS Plate (photo- When reversed stimulable fluorescent plate) is mounted in the cassette to record the X-ray image. This REGIUS Plate is designed to be reusable. Front Panel of Cassette Protects the REGIUS Plate.
  • Page 30 Usage of the Exposure-Only Cassette (images for the radiotherapy localization) Confirm that the image is used for radiotherapy localization purpose before Procedures ( “Loading the plate in the read-only cassette” -> “Exposure” -> “Loading the plate implementing the procedures in the system cassette” ) to record the exposed image data are described below. on the right using the read- only cassette.
  • Page 31 Usage of the Exposure-Only Cassette (for long object images) Confirm that the exposure will be made for long object purpose before implementing Procedures ( “Loading the plate in the read-only cassette” -> “Exposure” -> “Loading the plate in the system cassette” ) to record the long object image data are described below. the procedures on the left using the read-only cassettes.
  • Page 32 Care and Maintenance of the Exposure-Only Cassette To use the exposure-only cassette always in optimum condition, carry regular checks every week. Maintenance Task Works  Checking the surface grime and Clean the surface with lint-free cloth Cleaning  dampened in anhydrous ethanol. Checking the external damage If the damage is serious, stop using the (open/close lock, corner block and...
  • Page 33: Power On

    Power ON The following is a description of the procedure for switching on the REGIUS MODEL 190. Start and shut down of the REGIUS MODEL 190 are carried out from the REGIUS Console CS-1/CS- 2/CS-3 that controls it. The power should always be left on. In the case of emergencies or power failure, the power should be switched on, by following the procedure below.
  • Page 34: Daily Start Up (When Connected To Cs-1 Or Cs-3)

    Daily Start Up (When connected to CS-1 or CS-3) The REGIUS MODEL 190 starts automatically upon start up of the CS-1/CS-3.The following is a description of the procedure for start up of the REGIUS MODEL 190 while it is on sleep mode. For further details, refer to the CS-1/CS-3 Operation Manual.
  • Page 35: Daily Start Up (When Connected To Cs-2)

    Daily Start Up (When connected to CS-2) The REGIUS MODEL 190 starts automatically upon start up of the CS-2.The following is a description of the procedure for start up of the REGIUS MODEL 190 while it is on sleep mode. For further details, refer to the CS-2 Operation Manual.
  • Page 36: Inserting/Reading/Ejecting The Cassette

    Inserting/Reading/Ejecting the Cassette This section details the procedure for inserting the cassette into the REGIUS MODEL 190. Ensure that the message "READY" is READY displayed on the LCD of the REGIUS MODEL 190 and that the READY lamp is READY Lamp illuminated (Blue).
  • Page 37 A "BUSY" message and a counter "■ ■ ■ • • • " will be displayed on the LCD. BUSY • The counter on the LCD "■ ■ ■ • • • " will increment until the full value is reached at which point a "READY"...
  • Page 38: Erasing The Regius Plate

    Erasing the REGIUS Plate In order to maintain image quality, the REGIUS Plate should be erased before starting examination every morning. The cassettes mentioned below have to be erased before exposure: failure to do so may produce poor image quality. •...
  • Page 39 ERASE MODE 1 (High-speed erase mode) Ensure that "READY" is displayed on the READY LCD of REGIUS MODEL 190 and the READY lamp (blue) is illuminated. Press the "erase" button for at least three LCD Panel seconds. • The "erase" lamp located on the left of the Be careful not to push the "erase"...
  • Page 40 ERASE MODE 2 (Low-speed erase mode) Depress the "erase" button while the ERASE MODE 1 message "ERASE MODE 1" is displayed QUICK on the LCD panel. • The message "ERASE MODE 2" together with a counter "■ ■ ■ • • • SLOW" will appear on the LCD panel.
  • Page 41: Daily Shut Down (Sleep) (When Connected To Cs-1 Or Cs-3)

    The following is a description of the procedure for turning OFF the REGIUS MODEL 190 through the CS-1 or CS-3. For more details, refer to the CS-1 or CS-3 Operation Manual. Touch the "KONICA MINOLTA" button. • This will produce display of the system menu.
  • Page 42: Daily Shut Down (Sleep) (When Connected To Cs-2)

    The following is a description of the procedure for turning OFF the REGIUS MODEL 190 through the CS-2. For more details, refer to the CS-2 Operation Manual. [KONICA MINOLTA] Button Touch the "KONICA MINOLTA" button. • This will produce display of the system menu.
  • Page 43: Power Off

    Power OFF The process for switching off the power is detailed below. Ensure that the REGIUS MODEL 190 is in It is not usually necessary to Sleep Mode or the message "READY" switch OFF the power breaker appears on the LCD panel. Then depress when shut downing the unit.
  • Page 44 REGIUS MODEL 190 OPERATION MANUAL Ver.1.03 2004.12...
  • Page 45: 4 Troubleshooting

    Troubleshooting This chapter details procedures to be followed when troubles occur in the REGIUS MODEL 190. REGIUS MODEL 190 OPERATION MANUAL Ver.1.03 2004.12...
  • Page 46: Error Messages And Remedies

    Error Messages and Remedies Two types of error messages will be displayed on the LCD; error messages with error codes or without error codes. Error messages without error codes are "warning errors". When the same error repeats even after remedial action, contact your Technical Representative. Troubleshooting for errors with error codes REGIUS MODEL 190 ERROR MESSAGE...
  • Page 47 Handling errors with error codes REGIUS MODEL 190 ERROR MESSAGE REMEDY STATUS Operating ERROR [04904] The error with this error code will be displayed when both erasing lamps are broken. Once the error occurs, the REGIUS Initializing BAD LAMP CALL SVC MODEL 190 cannot be operated.
  • Page 48 Troubleshooting for errors without error code REGIUS MODEL 190 ERROR MESSAGE REMEDY STATUS Operating The front cover is open. DOOR OPEN Close the front cover. CST JAM? CLOSE DOOR READY The erasing lamp is broken. Contact your Service representative. BAD LAMP CALL SVC READY Align the cassette to be inserted to the left side.
  • Page 49 REGIUS MODEL 190 ERROR MESSAGE REMEDY STATUS ERASE MODE "x" ERASE MODE "x" Status: ERASE MODE "x" ALIGN CST TO LEFT NOTE Align the cassette to be inserted to the left side. ERASE MODE "x" BAD LAMP ALIGN CST TO LEFT ERASE MODE "x"...
  • Page 50: Handling Cassette Jams

    Handling Cassette Jams This section details the procedure to be followed upon occurrence of a cassette jam. Do not use the cassette that caused the jam. Please contact your Technical Representative. Cassette Jam This term describes a situation where the cassette is not ejected and is left in the REGIUS MODEL 190.
  • Page 51 Handling Cassette Jams Open the front door. • Opening the front cover automatically turns off the power of the drive unit. A warning label is affixed here. Do not place objects on the shelf located on the inside of the front door. Handle Pull out the handle from the handle holder located on the inside wall of...
  • Page 52 Turn the handle clockwise to move the transport unit When turning the handle, be toward you until it comes to careful that the handle does a full stop. not become detached. This may injure a hand by hitting the interior of the unit. Transport Unit Cassette Remove the jammed cassette...
  • Page 53 Back panel Front panel The back panel and front panel are separated and the back panel is attached to the If the cassette is jammed at cassette magnetizing plate. the position where it is not • The front panel is on the possible to be removed, contact your Technical transport unit.
  • Page 54 Turn the handle counterclockwise and return the transport unit until it The transport unit needs to reaches the home position mark. be returned to the position indicated by the home position mark. Gear Cover Home Position Mark Return the handle to the handle holder located on the inside of the front door.
  • Page 55 REGIUS MODEL 190 OPERATION MANUAL Ver.1.03 2004.12...
  • Page 56: Removal Of Foreign Objects From Cassette Insertion Slot

    Removal of Foreign Objects from Cassette Insertion Slot This section details the procedure to be followed in the event of a foreign object being dropped into the cassette insertion slot. Ensure that "READY" is displayed on the READY LCD panel. Using both hands, pull up the insertion guide of the cassette insertion slot along the arrow..
  • Page 57 Remove the foreign object from the cassette insertion slot by hand. Be careful not to allow the insertion guide to fall onto the original position. If the foreign objects are difficult to remove by hand, discontinue operation of the REGIUS MODEL 190 and contact your Technical Representative.
  • Page 58: Troubleshooting For Cassette

    Troubleshooting for Cassette Carry out the troubleshooting for the REGIUS Plate following the description below. Action against the Trouble When the surface of REGIUS Plate is damaged seriously: When the protective film covering the fluorescent surface of the REGIUS Plate is damaged or torn, immediately stop using the plate and replace it with new one.
  • Page 59: 5 Care & Maintenance

    Care & Maintenance This chapter details the procedure for care and maintenance of the REGIUS MODEL 190. REGIUS MODEL 190 OPERATION MANUAL Ver.1.03 2004.12...
  • Page 60 Care & Maintenance In order to ensure optimum performance, care and maintenance should be carried out following the procedures detailed below. Before cleaning, be sure to power off the power breaker and disconnect the power cable from the power outlet. Cassette Stacker 1.
  • Page 61 4. Cleaning the REGIUS Plate Dust may accumulate on the fluorescent surface of the REGIUS Plate, and may result in a defective image. To avoid such trouble, try to keep the cassette clean, and clean the REGIUS Plate once a week. Cleaning should be carried out on a level surface where it is not exposed to the direct light.
  • Page 62 Care & Maintenance Schedule Following maintenance cycle is for reference only; it may differ depending on usage. Maintenance by User Frequency Every Weekly Monthly Refer to 6 months. Maintenance Task Cleaning of the Cassette Stacker p.58 Cleaning of the REGIUS Plate p.59 Cleaning of the Exterior p.58...
  • Page 63: Specifications

    Specifications This chapter details the specifications of the REGIUS MODEL 190. REGIUS MODEL 190 OPERATION MANUAL Ver.1.03 2004.12...
  • Page 64 Device Type DIRECT DIGITIZER DD-941 Model Name DIRECT DIGITIZER REGIUS MODEL 190 CODE No. 0676 Safety Standard IEC60601-1, IEC60825 Exposure size (note 1) Regular : 14"X17" / 14"X14" / 11"X14" / 10"X12" / 8"X10" / 24X30cm / 18X24cm Mammography * : 24X30cm / 18X24cm Pantomography : 15X30cm Sampling Pitch (note 2) three types (43.75ı, 87.5ı...
  • Page 65: Appendix

    Appendix LCD list is described in this Appendix. REGIUS MODEL 190 OPERATION MANUAL Ver.1.03 2004.12...
  • Page 66: Lcd Display

    LCD Display Messages to be displayed on the LCD panel are described below. LCD in Normal Operation Liquid Crystal Display Status of REGIUS MODEL 190 LCD Display Refer to Power OFF or Sleep No Display p.39~41 Initializing INITIALIZING... p.31 Preparing for power OFF PREPARING POWER OFF p.39~41 Power OFF in process...
  • Page 67: Index

    Index Cassette Jam ......................p.20 / 44 / ~ 52 Cassette Magnetizing Plate......................p. / 51 Erasing Lamp .......................p.36 / 45~47 / 51 / Handle ........................p. / 49 / 50 / 52 Handle Holder ........................p. / 49 / 52 Initialization....................p. / 32 / 45 / 48 / 52 / 55 JM.............................p.