Setup; Lamp; Lamp Installation; Power - Chauvet ILS-625DCR User Manual

Color effect light
Hide thumbs Also See for ILS-625DCR:
Table of Contents

Advertisement

S
ETUP

Lamp

You will need to install a lamp prior to the initial operation of the fixture. A MSD250 high intensity discharge
lamp is included.
Warning!
When replacing the lamp, please wait 15 minutes after powering down to allow the
unit to cool down! Always disconnect from main power prior to lamp replacement.
Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp with
alcohol and wipe it with a lint free cloth before installation.
L AMP I NST AL L AT I O N
1)
Remove both thumbscrews located on the bottom of the
fixture.
2)
Pull out lamp socket plate as pictured to the right.
3)
If replacing the lamp, remove old lamp first.
4)
Holding the new lamp by its base, align the small pin on the
lamp with the small hole in the socket and insert the lamp
squarely until the retaining clips on the lamp socket secures
the lamp tightly.
5)
Clean the glass/envelope of the bulb with an alcohol wipe
or equivalent.
6)
Holding the lamp socket plate, insert the tip of the lamp into
the fixture with extreme care. Navigate the lamp all the way
until it reaches the reflector and the lamp base plate
touches the bottom plate of the fixture.
7)
Align the screw holes and fasten the thumbscrews back
onto the lamp socket plate.
8)
If you are replacing the lamp, you may want to log the
fixture hours in order to track the lamps use. Navigate to the
{FhrS} on the menu display to obtain this information.
9)
Turn the fixture on and adjust the lamp alignment screws
until the brightest most even area of the beam is in the
center of your spot. It may be necessary for you to use a
controller in order to command the fixture to display a white
beam on a flat surface with no gobos or colors.

Power

Your product is equipped with switch-selectable AC power setting.
Warning!
Verify that the power select switch on your unit
matches the line voltage applied. All fixtures must
be connected to circuits with a suitable Earth
Ground.
 To determine the power requirements for a particular fixture,
see the label affixed to the back plate of the fixture or refer to the fixture's specifications chart.
 A fixture's listed current rating is its average current draw under normal conditions.
 All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0%
to 100% switch.
 Before applying power to a fixture, check that the source voltage matches the fixture's
requirement.
 All fixtures must be connected to circuits with a suitable Earth Ground.
ILS-606 & ILS-625 User Manual
O NL Y F O R
S EN SI T I VI T Y
RE M O T E C O NT RO L
6
ILS-6xx Lamp Installation
Lamp alignment screws
P O WE R
PI N1 - C O M M
PI N2 - D M X
-
PI N3 - D M X
+
O U T P UT
F U SE
IN P UT
A d ju s t la m p p o s it i o n b y tu r n i n g s c r e w s A , B a n d C .
D is c o n n e c t p o w e r a n d w a i t 5 m in . b e f o r e o p e n in g .
M I C
CO NF I G UR AT I O N
M od el :
CH 1= PA N
S er ia l No :
CH 2= T IL T RO TA T I ON
P ow er :
CH 3= S HU T TE R / S HA K I NG
F use :
CH 4= G OB O
B ul b :
CH 5= CO LO R
CH 6= G OB O R O TA T IO N
CH 7= DI M M E R
Remove both thumbscrews
Slide switch up or down
depending on your line voltage.
2005-03-09/22:45