Chauvet Vue VI User Manual

Chauvet Vue VI User Manual

6-channel dmx-512 rotating led moonflower
Hide thumbs Also See for Vue VI:

Advertisement

Snapshot
Vue™ VI
Ok on Dimmer
Outdoor OK
Sound Activated
DMX512
Master/Slave
115V/230V Switch
Replaceable Fuse
User Serviceable
Duty Cycle
USER MANUAL
th
Chauvet, 3000 N 29
Ct, Hollywood, FL 33020 U.S.A.
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com

Advertisement

Table of Contents
loading

Summary of Contents for Chauvet Vue VI

  • Page 1 Snapshot Vue™ VI Ok on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL Chauvet, 3000 N 29 Ct, Hollywood, FL 33020 U.S.A. (800) 762-1084 – (954) 929-1115 FAX (954) 929-5560 www.chauvetlighting.com...
  • Page 2: Table Of Contents

    ABLE OF ONTENTS 1. BEFORE YOU BEGIN... 3 ... 3 HAT IS INCLUDED ... 3 NPACKING NSTRUCTIONS AC P ... 3 OWER ... 3 ONTACT ... 4 AFETY NSTRUCTIONS 2. INTRODUCTION ... 5 ... 5 EATURES DMX C ... 5 HANNEL UMMARY ...
  • Page 3: Before You Begin

    0% to 100% switch. Contact Us W o r l d W i d e General Information Technical Support World Wide Web Vue™ VI User Manual EGIN Chauvet Lighting 3000 North 29 Court Hollywood, FL 33020 voice: 954.929.1115 fax: 954.929.5560 toll free: 800.762.1084...
  • Page 4: Safety Instructions

    Avoid direct eye exposure to the light source while it is on. Caution! There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact CHAUVET at: 954-929-1115. Vue™ VI User Manual 2007-12-12/17:23...
  • Page 5: Introduction

    2. I NTRODUCTION Features • 6-channel DMX-512 rotating LED moonflower • Blackout/static/strobe • Individual control of red, green and blue LEDs within each cluster (3 total) • Built-in automated programs via master/slave or DMX • Built-in sound activated programs via master/slave or DMX Ad d i t i o n a l F e a t u r e s •...
  • Page 6: Product Overview

    Product Overview Tilt Adjustment Knob Dipswitches Sound Sensitivity Knob Microphone Power Output Connector Vue™ VI User Manual Hanging Bracket DMX Input Connector Output Connector AC Power Input & Fuse 2007-12-12/17:23...
  • Page 7: Setup

    Maximum recommended number of fixtures on a serial data link: 32 fixtures Data Cabling To link fixtures together you must obtain data cables. You can purchase CHAUVET-certified DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create your own cable please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic interference.
  • Page 8: Cable Connectors

    2. Connect the end of the cable coming from the controller which will have a (female) 3 pin connecto to the input connec 3. Then, proceed to connect from the output as stated above to the input of the following fixture and so on. CHAUVET Certified DMX Data Cables Order C Description DMX1.5 DMX Cable 1.5m/4.9ft...
  • Page 9: Stand-Alone/Master/Slave Fixture Linking

    Stand-Alone/Master/Slave Fixture Linking 1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the first fixture. 2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin connector to the input connector of the next fixture consisting of a (male) 3 pin connector.
  • Page 10: Operating Instructions

    4. O PERATING Operation Stand-Alone Mode (Sound-Active, Auto Mode, Strobe Mode, All On): This mode allows a single unit to run to the beat of the music, or the unit will auto change in Auto Mode. Set dipswitches position to Sound-Active or Auto Mode. Mode Sound-Active Auto Mode...
  • Page 11: Dmx Mode

    DMX Mode This mode allows the unit to be controlled by any universal DMX controller. If you are unfamiliar with DMX, please read the DMX Primer on page 16. Set dipswitches 1-9 to the desired DMX address. For help setting the address, see the “SETTING THE STARTING ADDRESS”...
  • Page 12 Vue™ VI User Manual Auto 8 Auto 9 Auto 10 Auto 11 Auto 12 Auto 13 Auto 14 Auto 15 Auto 16 Auto 17 Auto 18 Auto 19 Auto 20 Auto 21 Auto 22 Auto 23 Auto 24 Auto 25 Auto 26 Auto 27 Pod 3...
  • Page 13: Setting The Starting Address

    SETTING THE STARTING ADDRESS This DMX mode enables the use of a universal DMX controller device. Each fixture requires a "start address" from 1 to 512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address.
  • Page 14: Dmx Quick Reference Chart

    D MX QU ICK R EFER ENC E CHART DMX Address Quick Reference Chart DMX DIP #9 0 0 0 SWITCH SET 0=OFF #8 0 0 0 1=ON #7 0 0 1 X=OFF or ON #6 0 1 0 #1 #2 #3 #4 #5 0 0 0 0 0 32 64 96 128 160 192 224 256 288 320 352 384 416 448 480 1 0 0 0 0...
  • Page 15: General Troubleshooting

    If you still have a problem after trying the above solutions, please contact CHAUVET Technical Support at the location on the next page. Vue™ VI User Manual...
  • Page 16: Technical Support

    XLR male to female connectors. The shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET carries 3-pin XLR DMX compliant cables, DMX-10 (33’), DMX-4.5 (15’) and DMX-1.5 (5’) General Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently.
  • Page 17: Returns Procedure

    Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return.