ATTO Technology XstreamCORE FC 7550 Installation And Operation Manual

ATTO Technology XstreamCORE FC 7550 Installation And Operation Manual

Hide thumbs Also See for XstreamCORE FC 7550:
Table of Contents

Advertisement

Quick Links

Installation and Operation Manual
16-Gigabit Quad Fibre Channel to 12-Gigabit SAS intelligent Bridge
32-Gigabit Dual Fibre Channel to 12-Gigabit SAS intelligent Bridge
ATTO XstreamCORE®
ATTO XstreamCORE FC 7550
ATTO XstreamCORE FC 7600
©
2021 ATTO Technology, Inc. All rights reserved. All brand or
product names are trademarks of their respective holders.
No part of this manual may be reproduced in any form or by
any means without the express written permission of ATTO
Technology, Inc.
8/2021
PRMA-0464-000MD

Advertisement

Table of Contents
loading

Summary of Contents for ATTO Technology XstreamCORE FC 7550

  • Page 1 32-Gigabit Dual Fibre Channel to 12-Gigabit SAS intelligent Bridge © 2021 ATTO Technology, Inc. All rights reserved. All brand or product names are trademarks of their respective holders. No part of this manual may be reproduced in any form or by any means without the express written permission of ATTO Technology, Inc.
  • Page 2: Table Of Contents

    Table of Contents Table of Contents ....................................2 ATTO XstreamCORE Overview..............................4 ATTO XstreamCORE FC 7550 features, benefits ............................ 4 ATTO XstreamCORE FC 7600 features, benefits ............................ 5 ATTO XstreamCORE FC 7550 ................................ 6 Dimensions ......................................6 Cooling and airflow ................................... 6 Power ........................................
  • Page 3 SNMP-based monitoring ..................................17 SNMP Agent Setup ..................................18 SNMP Client Setup ..................................18 Email messages provide error notification ............................20 Update Firmware ..................................21 Using XstreamVIEW™ ..................................21 Using SFTP ....................................... 21 Interface Options ..................................22 Using XstreamVIEW™ System Manager .............................. 22 Opening an XstreamVIEW™...
  • Page 4: Atto Xstreamcore Overview

    ATTO XstreamCORE FC 7550 features, benefits • The ATTO XstreamCORE FC 7550 is a 16-Gigabit Quad Fibre SpeedWrite™ technology improves write performance to tape drives by up to 20% over SAS Channel to 12-Gigabit SAS intelligent Bridge configured with...
  • Page 5: Atto Xstreamcore Fc 7600 Features, Benefits

    ATTO XstreamCORE FC 7600 features, benefits • The ATTO XstreamCORE FC 7600 is a 32-Gigabit Quad Fibre SpeedWrite™ technology improves write performance to tape drives by up to 20% over SAS Channel to 12-Gigabit SAS intelligent Bridge configured with tape drives connected via SAS HBAs two independent 32Gb Fibre Channel ports and four 12Gb x4 •...
  • Page 6: Atto Xstreamcore Fc 7550

    ATTO XstreamCORE FC 7550 The ATTO XstreamCORE FC 7550 is a high-performance intelligent Bridge which adds 16-Gigabit Quad Fibre Channel connectivity to 12- Gigabit SAS or SATA storage devices. The XstreamCORE FC 7550 is available in an industry-standard Management ports 1U form factor for easy integration into racks.
  • Page 7 Fibre Channel Port Activity: A lit green FC port activity LED Fibre Channel Port Speed: A bi-color FC port speed LED is lit indicates FC traffic on the port, and OFF indicates no port as follows: Yellow = 16Gb/s, Green = 8Gb/s, and OFF = 4Gb/s. activity.
  • Page 8: Atto Xstreamcore Fc 7600

    ATTO XstreamCORE FC 7600 The ATTO XstreamCORE FC 7600 is a high-performance intelligent Bridge which adds 32-Gigabit Dual Fibre Channel connectivity to 12- Gigabit SAS or SATA storage devices. The XstreamCORE FC 7600 is available in an industry-standard Management ports 1U form factor for easy integration into racks.
  • Page 9 Fibre Channel Port Activity: A lit green FC port activity LED Fibre Channel Port Speed: A bi-color FC port speed LED is lit indicates FC traffic on the port, and OFF indicates no port as follows: Yellow = 32Gb/s, Green = 16Gb/s, and OFF = activity.
  • Page 10: Install The Xstreamcore

    Install the XstreamCORE If you have not already completed the instructions on the Quick Start page packed with your XstreamCORE, use the following instructions to install the XstreamCORE. Unpack the packing box; verify contents Connect the AC power cords from the XstreamCORE to the proper AC source outlets.
  • Page 11: Discover The Ip Address With Quicknav (Windows And Linux)

    Discover the IP address with QuickNAV (Windows Type in the user name and password. and Linux) The default user name and password values can be found on the bottom of the unit. The XstreamCORE is initially configured with DHCP enabled. It is best if you have access to a DHCP server. The user name is case insensitive and the password is case sensitive.
  • Page 12 Keypair regeneration -----END CERTIFICATE----- Keypairs may be uploaded via the “Certificate Management” The PEM file containing the keypair is regenerated by the page of the XstreamVIEW interface. controller if: CLI commands available for the user 1. It expires. This will be noted in the XstreamCORE event log.
  • Page 13 – XHIBIT ERTIFICATES AND FILE UPLOAD USEFUL FOR SETTING CERTIFICATE ATTRIBUTES OR UPLOADING A FILE IF A SELF SIGNED CERTIFICATE IS NOT DESIRABLE...
  • Page 14: Configure The Xstreamcore

    Configure the XstreamCORE To configure the ATTO XstreamCORE, use the ATTO XstreamVIEW™ System Manager GUI. Default values are appropriate for most configurations, but may be modified. The best way to access the XstreamCORE to view and change Port configurations settings is to use ATTO XstreamVIEW™ System Manager, a Follow the Preliminary steps.
  • Page 15: Map Devices

    Map Devices After getting an IP address and logging into the ATTO XstreamVIEW™ System Manager, you have options to map devices so that th e XstreamCORE can access the devices in your network. The ATTO XstreamCORE allows parallel SAS/SATA devices to The ATTO XstreamVIEW™...
  • Page 16: Mapping Devices With Smp

    Mapping Devices with SMP Drive Map Director assigns a Fibre target number to each If your devices do not support SMP you will be able shelf of storage and a Fibre LUN is reserved for each slot to use the AutoMap feature to map your storage devices. within the enclosure.
  • Page 17: Remote Monitoring, Management

    Remote Monitoring, Management The Ethernet port provides monitoring and management using the XstreamVIEW™ System Manager. Remote system monitoring may be set up through the You may designate which warning level a recipient receives. Remote Management page of the XstreamVIEW™ interface For example, a recipient with a critical severity level only (see XstreamVIEW System...
  • Page 18: Snmp Agent Setup

    The Simple Network Management Protocol (SNMP) facilitates This username and password are separate from the the exchange of management information between network Administrator and Read-Only credentials set in the Modify devices. Password section of the manual. The SNMPv3 credentials are An agent residing in the XstreamCORE takes information from only used for SNMPv3.
  • Page 19 SNMP XHIBIT VENTS TRIGGERING NOTIFICATION FOR EXTENDED OR STANDARD TRAP GENERATION SEVERITY LEVEL AND EXPLANATION Extended Extended Severity Event Traps Traps Explanation Level disabled enabled Aborted Warning A command has been aborted. Command Device Info A target device has failed, become offline or come online. Transition Fibre Channel Info...
  • Page 20: Email Messages Provide Error Notification

    Email messages provide error notification Email notification allows the XstreamCORE to send an Email If you are not already in the XstreamVIEW™ interface, type the IP address of your XstreamCORE in a standard message to you, a network administrator or other users when browser as found in Using XstreamView™...
  • Page 21: Update Firmware

    Select the file. Click Upload. The XstreamCORE firmware is distributed as a .zbd file from Wait until a success message is displayed. the ATTO Technology web site at www.atto.com. Download Click on the Restart button at the bottom of the page.
  • Page 22: Interface Options

    Interface Options Alternative methods to the ATTO XstreamVIEW™Interface may be used to manage the XstreamCORE. ATTO XstreamVIEW System Manager is the recommended interface. Access XstreamVIEW using standard browsers Google Chrome, Firefox, and Microsoft Edge. Using XstreamVIEW™ System Manager Each page in the ATTO XstreamVIEW™ System Manager The default user name and password values can be provides information and/or configuration parameters based found on the bottom of the unit.
  • Page 23: Using Ssh

    12. To verify that you have connected successfully, type help If you have difficulty using the serial port, verify that after the Ready prompt and press Enter. you have the correct settings and that your serial cable is less then two meters in length. If a list of all available commands does not appear on the screen, review the steps in this section, check the cable, or contact service personnel until the problem is solved.
  • Page 24: Appendix A Cabling

    Appendix A Cabling ATTO XstreamCORE SAS connections connect SAS or SATA storage devices into the Ethernet Storage Area Network (SAN). Use an Ethernet connection to use the ATTO XstreamVIEW™ System Manager. Make sure all cables are anchored securely at both ends with the proper connectors. SAS/SATA connections The XstreamCORE supports a wide variety of SAS &...
  • Page 25: Ethernet Management Connection

    Ethernet Management Connection The 100/1000BASE-T Ethernet ports provide remote need a crossover cable connecting directly to a computer. monitoring and management using the ATTO XstreamVIEW™ The ATTO XstreamCORE auto detects the Ethernet speed by System Manager. default. When you connect an Ethernet cable between the It is recommended to use a good quality Cat 5e or XstreamCORE and a 100/1000BASE-T connection, you may better cable...
  • Page 26: Appendix B Cli Provides Ascii-Based Interface

    Appendix B CLI Provides ASCII-based Interface The command line interface (CLI) provides access, configuration, and monitoring for ATTO XstreamCORE services through a set of ASCII commands. CLI commands may be entered through a serial port connection, active telnet session, or the Advanced page on the XstreamVIEW GUI.
  • Page 27: Cli Error Messages

    CLI Error Messages The following error messages may be returned by the Command line Interface ERROR. Invalid Command. Type 'Help' for command list. ERROR. Wrong/Missing Parameters Usage: <usage string> ERROR. Command Not Processed CLI Summary Reference A summary of the Command Line Interface commands, their defaults, and where you can find the specific command. Commands which have no default values associated with them have a blank entry in that column of the table.
  • Page 28 EthPortList EthPortList Exit exit FCCorePresent FCCorePresent FCDataRate auto get fcdatarate 1 FCLUNName FCLUNName all FCPortErrors get fcporterrors all FCPortList fcportlist FCSCSIBusyStatus busy get fcscsibusystatus FCSFPInfo get fcsfpinfo all FCWWName get fcwwname 1 FirmwareRestart firmwarerestart FlashImages flashimages Help help automap HGAddInitiator HGAddInitiator TestGroup 2000001086A6C440 HGAddLUN HGAddLUN TestGroup 5...
  • Page 29 IdentifyController disabled set identifycontroller enabled IdentifyLUN IdentifyLUN 10 Info info IPAddress 10.0.0.1 get ipaddress mp1 IPDHCP enabled set ipdhcp mp1 disabled IPDNSServer get ipdnsserver IPGateway 0.0.0.0 set ipgateway mp1 200.10.22.3 IPSubnetMask 255.255.0.0 get ipsubnetmask mp1 IPV6Prefix Set ipv6prefix 64 IsReserved isreserved Licenses Licenses...
  • Page 30: Command Explanations

    SerialPortEcho enabled get seriallportecho SNMP disabled set SNMP enabled SNMPDumpEngineID SNMPDumpEngineID SNMPDumpMIB snmpdumpmib SNMPExtendedTraps disabled get snmpextendedtraps SNMPTrapAddress 0.0.0.0 none set snmptrapaddress 6 192.42.155.155 all SNMPTraps disabled set snmptraps enabled SNMPUsername Set SNMPUsername bob SNTP enabled get sntp SNTPServer 129.6.15.30 set sntpserver 129.6.15.30 StopIdentifyLUN StopIdentifyLUN all...
  • Page 31 ControllerModel (Supported In-Band) DisplayInitiators (Supported In-Band) Reports the specific model and firmware information to the CLI. Displays the FC Port world-wide name of the connected initiators. get ControllerModel DisplayInitiators ControllerName (OEM Configurable, Supported In-Band) DumpCLILog (Supported In-Band) Provides a descriptive ASCII name assigned to the unit. This field Dumps the contents of the CLI command log to the current CLI is used by applications to identify individual units.
  • Page 32 EmailPassword sets the password used to authenticate the login FCDataRate (OEM Configurable, Supported In-Band) to the SMTP email server. The password must not be more than FCDataRate specifies the Fibre Channel data rate (7550: 64 characters. A password is not required if the email server does 4/8/16Gb;...
  • Page 33 FCWWName (Supported In-Band) Deletes an existing Host Group. FCWWName reports the World Wide Node Name of the Fibre HGDelete [HostGroupName | all] Channel interface referenced. HGDisplay (Supported In-Band) get FCWWName [fp | all] Displays Host Group status information for the specified Host FirmwareRestart (Supported In-Band) Group, or for all Host Groups.
  • Page 34 HttpsCertParams (Supported In-Band) IPDNSServer (OEM Configurable, Supported In-Band) Displays or sets the attributes used to generate the HTTPS Controls the current DNS Server address. If IPDHCP is enabled, certificate. All attributes are optional. C is Country with a fixed then this value is automatically detected. If IPDHCPis disabled, length of 2 characters.
  • Page 35 MinOpTemp (OEM Configurable, Supported In-Band) ReadOnlyUsername (OEM Configurable, Supported In-Band) Regulates/displays the minimum enclosure temperature alarm of Specifies the username used for all sessions: SSH, SFTP and XstreamVIEW. Username must be all lowercase, 1 to 32 the XstreamCORE in degrees Celsius. characters long, start with an alphabetical character, and may set MinOpTemp [0-15] only contain the following: {a-z,0-9,-,_,.}.
  • Page 36 SASMapByTopology (OEM Configurable, Supported In-Band) SerialPortEcho (OEM Configurable, Supported In-Band) SASMapByTopology specifies how target devices are mapped to Control/reports the status of the display of keyboard input. When LUNs. When enabled, LUNs are numbered based on the SAS enabled, all non-control character keyboard input is output to the topology, with gaps where there are open slots.
  • Page 37 SNMPUsername Time (Supported In-Band) Sets the SNMPv3 username and password or displays the Sets/displays the current time in a 24-hour format. If SNTP is SNMPv3 username. The username must be 1 to 32 characters enabled and at least one ethernet port is connected to a long, and may only contain the following: {a-z,A-Z,0-9}.
  • Page 38: Appendix D Standards And Compliances 7550

    Marking by the symbol indicates compliance of this ATTO device to the EMC Directive and the Low Voltage Directive of the European Union. The ATTO XstreamCORE FC 7550/7600 complies with Directive 2011/65/EC on the Restriction of the Use of Hazardous Substances in Electrical and Electronic Equipment RoHS2 (recast) and take the following exemptions: 6(c)- Copper allot containing up to 4% lead by weight.
  • Page 39: Appendix E Standards And Compliances 7600

    Appendix E Standards and Compliances 7600 The equipment described in this manual generates and uses radio frequency energy. If this equipment is not used in strict acc ordance with the manufacturer's instruction, it can and may cause interference with radio and television reception. Regulatory Notices FCC Notices (US only) This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
  • Page 40 The product has been certified and bears the Mark, as applicable, of the EMC and Product Safety authorities as indicated below: Safety: CU 72141224 04, EN 60950 , CE, CSA 60950 , UL 60950 , CB IEC60950-1 (all national deviations) Emissions/Immunity: FCC Part 15 Class , ICES-003, CE - EN550 2, EN55024, IEC61000-3-2, IEC61000-3-3...
  • Page 41: Appendix F Warranty Information

    ATTO Technology, Inc. limited warranty ATTO Technology, Inc. (“ATTO”) warrants to the original purchaser of this product (“Product”) that the Product is free from d efects in material and workmanship for the term described for this specific Product on ATTO's website (www.atto.com). ATTO's liability shall be limited to replacing or repairing any defective product at ATTO's option.

This manual is also suitable for:

Xstreamcore fc 7600

Table of Contents