ATTO Technology Celerity FC host adapters FC-44ES 4-Gb Installation And Operation Manual

Celerity fc series host adapters

Advertisement

Quick Links

Installation and Operation Manual
2-Gb FC quad channel host adapter with IOPC architecture
© 2006 ATTO Technology, Inc. All rights reserved. All brand or product names are trademarks of their respective
holders. No part of this manual may be reproduced in any form or by any means without the express written
permission of ATTO Technology, Inc.
03/2006
ATTO Technology, Inc.
Celerity FC host adapters
Celerity FC-44ES
4-Gb FC quad channel host adapter
Celerity FC-42ES
4-Gb FC dual channel host adapter
Celerity FC-41ES
4-Gb FC single channel host adapter
Celerity FC-42XS
4-Gb FC dual channel host adapter
Celerity FC-41XS
4-Gb FC single channel host adapter
Celerity FC-21PS
2-Gb FC single channel host adapter
Celerity FC-24XL
Document Control Number: PRMA-0344-000

Advertisement

Table of Contents
loading

Summary of Contents for ATTO Technology Celerity FC host adapters FC-44ES 4-Gb

  • Page 1 2-Gb FC quad channel host adapter with IOPC architecture © 2006 ATTO Technology, Inc. All rights reserved. All brand or product names are trademarks of their respective holders. No part of this manual may be reproduced in any form or by any means without the express written permission of ATTO Technology, Inc.
  • Page 4: Atto Provides Fibre Channel Solutions

    Environmental & physical specifications External connectivity Software specifications Celerity FC-24XL Adapter Hardware specifications IOPC specifications Advanced FC capabilities PCI Bus Specifications Environmental & physical specifications External connectivity Software specifications Celerity Selection Guide ATTO Technology Inc.Celerity FC Storage Adapters Installation and Operation Manual Contents...
  • Page 5: Table Of Contents

    FCC standards: radio and television interference Canadian standards European standards Declaration of Conformity Usage restrictions Appendix B Accessories ...iii Optical Cables Fibre Channel and iSCSI solutions SCSI solutions Software Appendix C SCSI adapter selection guide ...iv Appendix D Contact ATTO Technology, Inc..v...
  • Page 6: Hardware Specifications

    • Conforms to PCI Express Base Spec 1.0a • Conforms to PCI Express CEM Spec 1.0a 1 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual • PCI Express to PCI/PCI-X Bridge spec 1.0 Environmental & physical specifications •...
  • Page 7 Celerity FC-42ES Adapter The Celerity FC-42ES is a dual-channel host adapter, providing port density for Enterprise server and workstation applications. With 4-Gb FC speeds of up to 800 MB/second per channel, the FC-42ES supports the most demanding application requirements. Additionally the FC-42ES takes advantage of the latest in host interconnect technology, PCI Express, a serial, high-speed connection that supports aggregate throughput up to 2 GB/second (x8 PCIe).
  • Page 8 • Supports PCI Express Base Spec 1.0a and CEM Spec 1.0a • Supports PCI Express to PCI/PCI-X bridge spec 3 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual Environmental & physical specifications • Conforms to PCIe low profile form factor specifications •...
  • Page 9 Celerity FC-42XS Adapter The dual-channel Celerity FC-42XS host adapter provides the highest available throughput for Fibre Channel applications while protecting technology investments via backward compatibility with existing infrastructure. With speeds of up to 800 MB/sec. per channel, the FC- 42XS is capable of supporting the most intensive data applications.
  • Page 10 • 64-bit, 133 MHz PCI-X • PCI-X 1.0a compliant • PCI 2.2 compliant 5 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual • 3.3V PCI signaling only Environmental & physical specifications • Conforms to PCI low profile form factor standards •...
  • Page 11 Celerity FC-21PS Adapter The Celerity FC-21PS Fibre Channel host adapter provides a single 2-Gb Fibre Channel connection from host devices to the Storage Area Network (SAN) fabric. The FC-21PS supports the leading operating systems, providing a single solution for all connectivity needs. As with all Celerity FC products, the FC-21PS is designed for high-quality data transmission, ensuring that critical information is delivered correctly the first...
  • Page 12 Gb and 1-Gb Fibre Channel • Supports target and Initiator modes • Supports Windows FDMI and WMI • Exclusive Advanced Data Streaming (ADS 7 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual Technology PCI Bus Specifications • 64-bit, 133 MHz PCI-X •...
  • Page 13: Celerity Selection Guide

    Celerity Selection Guide Product FC-44ES Features Fibre Channel ports FC protocol 4-Gb Maximum Transfer 1.6 GB/sec Rate (half duplex) Maximum Transfer 2 GB/sec Rate (full duplex) Bus type PCIe Bus characteristics 8 lane Optical interface SFP LC Maximum cable 300m@2-Gb length 150m@4-Gb Low profile form...
  • Page 14: Glossary

    (PIO or programmed I/O) 9 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual protocols are able to run over Fibre Channel hardware.
  • Page 15 Term fabric a Fibre Channel switch or two or more Fibre Channel switches interconnected to physically transmit data between any two N_Ports on the switch or switches Fibre Channel F_port a port in the Fibre Channel fabric where a N_port may attach FL_port a port in the Fibre Channel fabric where a NL_port may attach in an arbitrated loop frame...
  • Page 16: Hardware Installation

    The WWN listed on your host adapter is assigned to the first channel (0). Sequential WWNs apply for additional channels. 11 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual on page 9 for a list of related web sites. WWN 0...
  • Page 17: Bracket Details

    Bracket details Exhibit 3-1 FC-44ES Adapter Speed LEDs If Link LED is lit, the storage indicate 4Gb Exhibit 3-2 FC-42ES Adapter Speed LEDs indicate 4Gb storage adapter is online Exhibit 3-3 FC-41ES Adapter Link LEDS adapter is online Speed LED indicate 4Gb SFP LC optical connectors...
  • Page 18 FC24XL Exhibit 3-6 FC-21PS Adapter If LED lit, the storage If LED lit, indicates the adapter is online channel is using 2-Gb FC SFF duplex LC optical connector 13 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual...
  • Page 19: Adapter Board Details

    Adapter board details Exhibit 3-8 FC-44ES FC controller SFP LC optical connectors PCI Express connector Exhibit 3-9 FC-42ES Non-RoHS c o n tro lle r S F P L C o p tic a l c o n n e c to rs P C I E x p re s s c o n n e c to r...
  • Page 20 Exhibit 3-11 FC-41ES SFP LC optical connector 15 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual P C I E xp re ss co n n e cto r FC controller PCI Express connector...
  • Page 21 Exhibit 3-12 FC-42XS F C c o n tro lle r S F P L C o p tic a l c o n n e c tors P C I-X c o n n e c to r Exhibit 3-13 FC-41XS FC controller SFP LC optical...
  • Page 22 Exhibit 3-15 FC-24XL FC controllers Intel 80331 XScale PCI-X connector 17 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual...
  • Page 24: Configuring And Updating Drivers

    Installation CD shipped with your adapter, a folder containing the latest downloaded and expanded driver, or a Celerity FC installation floppy disk. 19 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual Updating hardware flash on page 22 for , to download the www.attotech.com...
  • Page 25 Adding a Celerity FC adapter to an existing Windows installation Note Complete this installation procedure before attaching any devices to the adapter. Complete the steps in Upgrading your existing Celerity FC driver on page 19 to pre-install the driver. Shutdown Windows when Setup prompts you to do so.
  • Page 26: Mac Os X Driver Installation, Update

    If updating an existing Celerity FC driver, at the command prompt type rmmod celerityfc 21 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual Create a floppy disk from a Celerity FC driver download from the ATTO Technology website Download the latest driver software from the ATTO web site, www.attotech.com.
  • Page 27: Updating Hardware Flash

    CD-ROM drivers are not loaded at this point in the system boot process. Reboot the PC. During the reboot, an ATTO Technology banner displays that the host adapter was detected. Enter Control-F when prompted to begin the set-up utility within a few seconds after the banner appears.
  • Page 28: Troubleshooting

    Device Manager, the external devices or connection may not be working properly. 23 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual 6 Troubleshooting • Check that Fibre Channel devices are plugged into an AC outlet and are turned on before you add power to your computer.
  • Page 29: Linux

    Uninstall. Reboot the system and repeat the installation process. If problems persist, contact your authorized ATTO Technology representative. adapter’s host number. This file contains details such as link status, connection speed and discovered devices. Configuring and Note a.
  • Page 30: Appendix A Standards And Compliances

    Some ATTO Celerity cards comply with Directive 2002/95/EC on the Restriction of the Use of Hazardous Substances in Electrical and Electronic Equipment (RoHS). Contact your ATTO representative regarding RoHS compliant products. i ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual WARNING...
  • Page 31: Usage Restrictions

    Usage restrictions The use of optical instruments with this product will increase eye hazard. The multimode transceiver is a Class 1 laser product complying with IEC 825-1 and FDA-21 CFR 1040.11. To meet laser safety requirements, the transceiver shall be operated within the maximum ratings.
  • Page 32: Appendix B Accessories

    CBL-LCSC-010 10 m. 50/125 optical cable (LC to SC) A variety of iSCSI, Fibre Channel and SCSI products are also available from ATTO Technology. Please contact your ATTO sales representative for product descriptions and part number information. Fibre Channel and iSCSI solutions...
  • Page 33: Appendix C Scsi Adapter Selection Guide

    Appendix C SCSI adapter selection guide Ultra 320 Product Features UL5D UL4D UL4S Maximum Transfer Rate (MB/sec.) Low Voltage Differential Single-ended SCSI Number of SCSI channels Number of SCSI IDs supported 12.5 12.5 12.5 Cable distances (m) Large file transfers 32-bit PCI compatible 64-bit PCI compatible 33 MHz PCI...
  • Page 34: Appendix D Contact Atto Technology, Inc

    Amherst, New York 14068 (716) 691-1999 • voice (716) 691-9353 • fax http://www.attotech.com ATTO Technology can also be reached via e-mail at the following addresses: Sales Support: Technical Support: v ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual sls@attotech.com...

Table of Contents