ATTO Celerity Fibre Channel Host Adapters
Installation and Operation Manual
8-Gb FC quad channel PCIe 2.0 host adapter
8-Gb FC dual channel PCIe 2.0 host adapter
8-Gb FC single channel PCIe 2.0 host adapter
4-Gb FC quad channel PCIe host adapter
4-Gb FC dual channel PCIe host adapter
4-Gb FC single channel PCIe host adapter
4-Gb FC single channel PCIe host adapter
4-Gb FC dual channel PCI-X host adapter
4-Gb FC single channel PCI-X host adapter
Celerity FC-84EN
Celerity FC-82EN
Celerity FC-81EN
Celerity FC-44ES
Celerity FC-42ES
Celerity FC-41ES
Celerity FC-41EL
Celerity FC-42XS
Celerity FC-41XS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Celerity FC-41EL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ATTO Technology Celerity FC-41EL

  • Page 1 4-Gb FC quad channel PCIe host adapter Celerity FC-42ES 4-Gb FC dual channel PCIe host adapter Celerity FC-41ES 4-Gb FC single channel PCIe host adapter Celerity FC-41EL 4-Gb FC single channel PCIe host adapter Celerity FC-42XS 4-Gb FC dual channel PCI-X host adapter Celerity FC-41XS...
  • Page 2 Technical support: Monday -- Friday, 8am-8pm EST techsupp@attotech.com © 2008 ATTO Technology, Inc. All rights reserved. All brand or product names are trademarks of their respective holders. No part of this manual may be reproduced in any form or by any means without the express written permission of ATTO Technology, Inc.
  • Page 3: Table Of Contents

    Appendix C ATTO Adapter Selection Guides ...v Appendix D Standards, Compliances: 8Gb adapters ...viii FCC standards: radio and television interference Canadian standards European standards Appendix E Standards, Compliances: 4Gb adapters ...ix Appendix F Safety, Warranty ...x Safety ATTO Technology, Inc. limited warranty Contents...
  • Page 4: Atto Provides Fibre Channel Solutions

    Install drivers from the Installation CD for your operating system. Refer to page 13. 1 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual Fibre Channel provides a logical, point-to-point, serial channel for the transfer of data between a buffer at a source device and a buffer at a destination device.
  • Page 5: Celerity Fc-84En Adapter

    Celerity FC-84EN supports the most demanding application requirements, including high- definition video, rich content databases and other high-bandwidth environments. ATTO Celerity host adapters are an integrated family of advanced storage connectivity solutions that are designed to provide reliable connectivity, intelligence and scalability.
  • Page 6: Celerity Fc-82En Adapter

    • Conforms to PCI Express Base Spec 2.0 Conforms to PCI Express CEM Spec 2.0 • PCI Hot Plug spec 1.0 3 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual Environmental & physical specifications • Length: 6.6 inches •...
  • Page 7: Celerity Fc-81En Adapter

    Celerity FC-81EN supports the most demanding application requirements, including high- definition video, rich content databases and other high-bandwidth environments. ATTO Celerity host adapters are an integrated family of advanced storage connectivity solutions that are designed to provide reliable connectivity, intelligence and scalability.
  • Page 8: Celerity Fc-44Es Adapter

    • FC Class 3 support • Local management and diagnostics • Buffer credits: 8 @ 512 Bytes; 8 @ 2 Kilobytes 5 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual Advanced FC capabilities • Supports SNIA HBA API •...
  • Page 9: Celerity Fc-42Es Adapter

    Celerity FC-42ES Adapter The Celerity FC-42ES is a dual-channel host adapter providing port density for Enterprise server and workstation applications. With 4-Gb FC speeds of up to 800 MB/sec. per channel, the FC-42ES supports the most demanding application requirements. Additionally the FC-42ES uses the latest in host interconnect technology, PCI Express, a serial, high- speed connection that supports aggregate throughput up to 4 GB/sec.
  • Page 10: Celerity Fc-41Es Adapter

    • ANSI Fibre Channel: FC-FS, FC-AL, FCP, FC- AL2, FC-PLDA, FC-FLA • Flash ROM for easy field upgrades 7 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual • FC Class 3 support • Local management and diagnostics •...
  • Page 11: Celerity Fc-41El Adapter

    With 4-Gb FC speeds of up to 800 MB/sec., the FC-41EL supports the most demanding application requirements. The FC-41EL uses the latest in host interconnect technology, PCI Express, a serial, high-speed connection that supports aggregate throughout up to 2 GB/sec.full-duplex.
  • Page 12: Celerity Fc-42Xs Adapter

    • ANSI Fibre Channel: FC-FS, FC-AL, FCP, FC- AL2, FC-PLDA, FC-FLA • Flash ROM for easy field upgrades 9 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual • FC Class 3 support • Local management and diagnostics •...
  • Page 13: Celerity Fc-41Xs Adapter

    Celerity FC-41XS Adapter The single-channel Celerity FC-41XS provides speeds of up to 800 MB/sec. using full 4-Gigabit Fibre Channel performance while being fully backward- compatible with existing 2-Gb and 1-Gb Fibre Channel infrastructure, protecting existing technology investments. It is capable of supporting the most data- intense applications.
  • Page 14 1 Performance ceiling is Performance constrained by bus transfer speed. Backward compatible to 32-bit and 33 MHz PCI 2 ATTO ExpressStripe for OS X available; Express Power Center and other software RAID supported for Windows 11 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual FC-84EN 8-Gb 3.2 GB/sec...
  • Page 16: Install Drivers

    Click on the menu item containing the words Install Driver for the version of Windows you are using. 13 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual 2 Install Drivers ATTO Celerity adapters ship with the latest firmware installed.
  • Page 17 Creating a boot disk Note The procedure described below does not apply to Windows Server 2003 for Itanium systems because the Celerity FC driver does not support boot functionality on Itanium systems. Start Windows text mode setup as found in the instructions provided with Windows.
  • Page 18: Windows

    ATTO website. Verify the version of your adapter and drivers based on your operating system: 15 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual Download the appropriate version of the device driver from the ATTO website.
  • Page 20: Hardware Installation

    WWN 0 all adapters WWN 1: 44ES, 42ES, 42XS, 82EN, 84EN WWN 2 44ES, 84EN WWN 3 44ES, 84EN 17 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual Installation CAUTION CAUTION Celerity FC host adapters contain components that are sensitive to electrostatic discharge (ESD).
  • Page 21: Bracket Details

    Bracket details Exhibit 3-1 FC-84EN Exhibit 3-2 FC-82EN full height and low profile Exhibit 3-3 Exhibit 3-4 FC-81EN full height and low profile Exhibit 3-5 FC-44ES full height...
  • Page 22 Exhibit 3-6 FC-42ES low profile, full height Exhibit 3-7 FC-41ES low profile and full height 19 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual Exhibit 3-8 FC-41EL low profile, full height Exhibit 3-9 FC-42XS low profile and full height...
  • Page 23: Adapter Board Details

    Exhibit 3-10 FC-41XS low profile and full height Adapter board details Exhibit 3-11 FC-84EN...
  • Page 24 Exhibit 3-12 FC-82EN Exhibit 3-13 FC-81EN 21 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual...
  • Page 25 Exhibit 3-14 FC-44ES Exhibit 3-15 FC-42ES FC controller SFP LC optical connectors PCIe connector...
  • Page 26 Exhibit 3-16 FC-41ES FC controller SFP LC optical connector PCIe connector Exhibit 3-17 FC-41EL SFP LC optical connector PCIe connector 23 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual...
  • Page 27 Exhibit 3-18 FC-42XS Exhibit 3-19 FC-41XS...
  • Page 28: Updating Hardware Flash, Drivers

    Click Update to update your flash ROM. 25 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual Reboot your system for the changes to take effect.
  • Page 29 After the download has completed, process the downloaded file: • On OS X, expand the .tgz file, then double click on the installer icon. • On Windows, run the downloaded .exe file. • On Linux, double click on the .bin file. If the executable bit is not set, run sh /path/to/bin.
  • Page 30: Troubleshooting

    This chapter contains solutions for the most common problems you might encounter. If you need additional assistance, please refer to the ATTO Technology website, www.attotech.com, or contact an authorized ATTO Technology representative. General suggestions • Check each cable connection on every device.
  • Page 31: Linux

    Reload the driver (see Flash, Drivers Reboot the system and repeat the installation process. If problems persist, contact your authorized ATTO Technology representative. Examine the contents of the file(s) /proc/scsi/celerityfc/X, where X is the adapter’s host number. This file contains details Updating Hardware such as link status, connection speed and discovered devices.
  • Page 32: Appendix A Glossary

    Logical Unit Number: an identifier for a logical unit (0-7) multi-mode fiber an optical fiber which can carry several beams of light at once i ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual...
  • Page 33 Term Definition N_port a port attached to a node used with point to point or fabric configurations NL_ port a port attached to a node in Fibre Channel arbitrated loop or fabric loop configuration originator an initiating device; a component which originates a command parity checking a method which verifies the accuracy of data transmitted over the SCSI bus by adding one bit in the transfer to make the sum of all the bits either odd or even (for odd or even parity);...
  • Page 34: Appendix B Accessories

    CBL-LCSC-0033 m. 50/125 optical cable (LC to SC) CBL-LCSC-01010 m. 50/125 optical cable (LC to SC) A variety of iSCSI, Fibre Channel, SAS and SCSI products are also available from ATTO Technology. Please contact your ATTO sales representative for product descriptions and part number information.
  • Page 35: Appendix C Atto Adapter Selection Guides

    Appendix C ATTO Adapter Selection Guides Contact your ATTO representative or visit the ATTO website for details on all ATTO products. ExpressPCI SCSI host adapters Product Features Max. transfer rate (MB/sec.) Low Voltage Differential Single-ended SCSI Number of SCSI Channels...
  • Page 36 • SUSE) Mac OS X • Low profile • Performance ceiling constrained by PCIe bus transfer speed Future support v ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual H380 H30F 4 GB/sec. 4.0 GB/sec. • • 0/16...
  • Page 37: Declaration Of Conformity

    Appendix D Standards, Compliances: 8Gb adapters The Technical Specification sheet for each Celerity FC host adapter lists certifications for that model. Models covered by this page include the Celerity FC-84EN, FC-82EN and the FC-81EN. FCC standards: radio and television interference This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
  • Page 38: Appendix E Standards, Compliances: 4Gb Adapters

    Use of Hazardous Substances in Electrical and Electronic Equipment (RoHS). Contact your ATTO representative regarding RoHS compliant products. The following apply to the Celerity FC-42XS host adapter only: vii ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual...
  • Page 39: Appendix F Safety, Warranty

    ATTO host adapter and void the warranty. ATTO Technology, Inc. limited warranty ATTO Technology, Inc. warrants to the original purchaser of this product that it is free from defects in material and workmanship as described in the ATTO Technology website, www.attotech.com, for three years.
  • Page 40 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual...