5.Nominal Size Selection Method 
5.1 Nominal Size Selection Chart 
< For Water > 
Nominal Size 
(A) 
ΔP:Differential  Press. (MPa)
 
Fig.6 
Example of Selection 
When the inlet pressure (P
) is 0.5 MPa , the reduced pressure (P
) is 0.3 MPa and 
1
2
3
the flow rate is 7m
/h, for instance , the size of the pressure reducing valve is 
selected as follows. Find the intersection point(A) of the differential pressure 
3
of 0.2 MPa with the flow rate of 7 m
/h, the point(A) is between line of size 25A 
and 32A. 
Choose larger size 32A for application.
-5-