(14) If the large valve is used for gas, install a reducer to prevent excessive 
flow speed. ( The flow speed made in pipings is appropriate, if it is 15m/s 
or less.) 
(15) Above the center of the pipe line, be sure to reserve enough space larger 
than H
(Fig.3). Please see the following table. 
2
Nominal Size  15A  20A
H
 
2
7. Operating Procedure 
7.1 Precautions for pressure reducing valve operation 
  Warning 
 Do not touch the valve directly with bare hands. 
※Doing so may result in burns. 
  Caution
 
(1) Close the stop valves before and after the pressure reducing valve, and 
remove  all  foreign  matter  and  scales  via  the  by-pass  line  before 
operation. 
※Failure to do so may prevent the valve from functioning correctly.
(2) When the adjust pressure, slowly turn the adjusting screw 
※ Incorrect  adjustment  may  cause  hunting,  water  hammer,  etc., 
resulting in damage to the valve and other equipment. 
(3) Remove condensate completely from the line, and close the stop valves 
before and after the valve when not using it for long periods of times. 
※Rust generated in the valves and lines may cause malfunction. 
                                     
25A
32A
500  500
500
650
-10-
Table  7                                  (mm) 
40A
50A
65A
650
650
800
Fig.11
 
                                 
80A  100A  125A 150A
800  1000  1200 1400
■EPDT-096b■