4.Operation 
 
Fig.4 
 
 
 
 
 
 
 
Fig.5 
                                     
If the adjusting screw⑬ is turned right, the 
diaphragm⑨ will be depressed with a adjusting 
spring ⑫   and  valve  disc ④   connected  with 
spindle⑤ will open. 
The fluid which flowed in from the inlet side 
carries  out  the  action  which  pushes  up 
diaphragm⑨ through a sensing pipe at the same 
time it flows into a outlet side through the 
valve disc④ upper part. 
Load  to  diaphragm⑨  balances  with  load  of 
adjusting spring⑫, and it adjust the opening 
of  main  valve  to  regulate  the  reducing 
pressure. 
With closing stop valve at the outlet side by 
little by little, the load to diaphragm⑨ will 
be increased because of increasing in reduced 
pressure.    Increasing  load  to  diaphragm⑨ 
overcomes the load of adjusting spring⑫, and 
then closes the main valve. 
-4-
                                 