5.Nominal Size Selection Method; 5.1 Nominal Size Selection Chart - Yoshitake DP-10 Series Instruction Manual

Table of Contents

Advertisement

5.Nominal Size Selection Method
5.1 Nominal Size Selection Chart
■Piston type (For steam)
(DP-10/13/15/17/10D/13D/15D/17D)
Nominal
Size
【Example】
Under the following conditions, the appropriate nominal size would be determined as
described below. Inlet pressure(P
(W): 400kg/h. First, find the point[A] where (P
[B] where a line drawn straight down from point[A] intersects the (W) line. In the
above example, the point[B] is located between the 15A and 20A nominal size valves,
so larger size of 20A should be selected.
・65A
): 0.7MPa; Outlet pressure(P
1
) and (P
) intersect. Next find the point
1
2
-5-
[A]
[B]
): 0.5MPa; Flow rate
2
■EPDT-028d■