6.2 Precautions before operation  
Caution
 
(1) Since it is weight thing, this product should use lifting equipment etc., 
and please support a product certainly and install it in piping. 
※There is a possibility that it may be injured, by fall of product. 
(2) Do not disassemble the valve unreasonably. 
※ Disassembling  the  valve  at  your  discretion  may  affect  the  original 
performance. 
(3)  Remove  foreign  matter  and  scales  from  the  lines  before  connecting  the  valve. 
※Failure to do so may prevent the valve from functioning correctly. 
(4) Install a strainer at the valve inlet side. 
※Failure to do so may hamper correct pressure control, which affects the 
original performance. 
※By sunshine or atmosphere temperature rise, the fluid in piping carries 
out volume expansion, failure of the valve and the external leak of fluid 
occur, and there is danger of circumference contamination. 
(5) Install a safety valve at the valve outlet sides for alarms. 
※Failure to do so prevents problem identification, resulting in equipment 
damage. 
(6) Install a pressure gauge at both the inlet and outlet sides of the valve. 
※Failure to do so may hamper correct pressure adjustment. 
(7)  For  gas  application,  install  a  trap  to  the  inlet  sides  of  the  valve  to  prevent 
drainage problem. 
※Failure to do so may result in drainage problem, affecting the original 
performance. 
(8)  When  installing  quick  open  and  close  valves,  such  as  a  solenoid  valve,  secure 
at least 3 m from the valve. 
※Failure to do so may result in malfunction or drastically shortened 
service life. 
(9)  When  reducing  pressure  in  two  stages,  secure  at  least  3  m  between  the  valves. 
※ Failure  to  do  so  may  result  in  malfunction,  affecting  the  original 
performance. 
(10) Install the valve in proper direction of the fluid flow. 
※Failure to do so may affect the original performance. 
(11) Do not apply excessive load, torque or vibration to the valve. 
※Doing so may result in malfunction or drastically shortened service life.
(12) Pipes can be installed either horizontally or vertically except over the 
size of 100A. 
(13) The safety valve should be set as described below. 
Setting pressure of a reducing valve (MPa) 
0.8 and above 
                                     
Table 6 Safety valve setting pressure table 
0.1 or less 
0.11-0.4 
0.41-0.6 
0.61-0.8 
-9-
Setting pressure of a safety valve (MPa) 
Setting pressure of a reducing valve 
Setting pressure of a reducing valve 
Setting pressure of a reducing valve 
Setting pressure of a reducing valve 
Setting pressure of a reducing valve +15% 
                                 
+0.05 or more 
+0.08 or more 
+0.1 or more 
+0.12 or more 