Connection List/Dial Out

61200176L2-1

PPP/Max Failure

Write security: 3; Read security: 5
Due to the nature of PPP, configuration options may not be agreed upon
between two PPP peers. This value is the number of configuration-naks
that should occur before an option is configuration-rejected. This allows
a connection to succeed that might otherwise fail. The possible values are
5 (def), 10, 15 and 20.
The dialing parameters for establishing this connection are defined under
this menu.

Dial Out/Number 1

Write security: 3; Read security: 5
This is the first number used for dialing up this connection.

Dial Out/Number 2

Write security: 3; Read security: 5
This is the second number used for dialing a second B-channel when
adding bandwidth. If BACP/BAP is negotiated, this number is not nec-
essary. If this number is not specified and BACP/BAP is not used, the
Number 1 number is re-dialed when adding bandwidth.

Dial Out/Call Type

Write security: 3; Read security: 5
The call type can be configured in four different ways:
Speech
Speech directs the call control software to request a
Mu-law encoded speech circuit as the bearer capabil-
ity for the outgoing calls. The speech option is used
with an ISDN line configured for voice service. In
some areas, voice service costs less than data ser-
vices. A speech call type does not always guarantee
an end-to-end digital connection with some local and
long distance carriers.