In-Place Sanitization; Routine Maintenance - Cecilware MT-2-ULAF Operator's Manual

Cecilware mt-2-ulaf dispensers: user guide
Hide thumbs Also See for MT-2-ULAF:
Table of Contents

Advertisement

Available languages

Available languages

wall (see figure 13).
5 - Insert the auger into the evaporator taking care to
accompany it to the end so as to prevent it from hitting
against the rear wall (see figure 14).
6 - Install the outer spiral. Slide it over the evaporator until its
front notch engages with the exposed end of the auger
shaft (see figure 15).
7 - Push the bowl towards the rear wall of the unit until it fits
snugly around the gasket and its front fastening hooks are
Ugolini spa
figure 13
figure 14
figure 15
properly engaged (see figure 16).
8 - Use fresh product to chase any remaining sanitizer from
the bottom of the bowl(s). Drain this solution. Do not rinse
out the machine.

5. 4 IN-PLACE SANITIZATION

The In-Place Sanitization prior to starting the machine may be
performed, if needed, only as further precaution, in addition to
the Disassembled Parts Sanitization described before, but
never in lieu of it.
1 - Prepare two gallons of a warm (45-60°C / 120-140 °F)
s a n i t i z i n g s o l u t i o n ( 1 0 0 P P M a v a i l a b l e c h l o r i n e
concentration or 1 spoon of sodium hypoclorite diluted with
half a gallon of water) according to your local Health
Codes and manufacturer's specifications.
2 - Pour the solution into the bowl(s).
3 - Using a brush suitable for the purpose, wipe the solution
on all surfaces protruding above the solution-level and on
the underside of the top cover(s).
4 - Install the top cover(s) and operate the unit. Allow the
solution to agitate for about two minutes. Drain the solution
out of the bowl(s).
5 - Use fresh product to chase any remaining sanitizer from
the bottom of the bowl(s). Drain this solution. Do not rinse
out the machine.

6 ROUTINE MAINTENANCE

1 - Daily: inspect the machine for signs of product leaks past
seals and gaskets. If proper assembly does not stop leaks
around seals or gaskets, check for improper lubrication,
worn or damaged parts. Replace parts as needed.
2 - Monthly on MT 1P, MT 2 and MT 3 models: remove the
dust from the condenser filter. A blocked filter will reduce
ATTENTION
Before any disassembly and/or cleaning procedure
make sure that the dispenser is disconnected from its
power source by unplugging it or switching off the 2-
pole wall breaker.
performance and could cause compressor failure.
Remove the only left panel (from faucet side) unscrewing
MT UL AF Black
figure 16
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mt-2-ulaf-blMt 1pMt 2Mt 3

Table of Contents