Cecilware Vista GB5MV-10-LD Operation Manual

Cecilware Vista GB5MV-10-LD Operation Manual

Cecilware corp. hot beverage maker operation manual

Advertisement

Quick Links

GB6MP-10-LD-U
GB5MV-10-LD
GB8MP-10-LD-U
Operation Manual
NL48P July 2005

Advertisement

Table of Contents
loading

Summary of Contents for Cecilware Vista GB5MV-10-LD

  • Page 1 GB6MP-10-LD-U GB5MV-10-LD GB8MP-10-LD-U Operation Manual NL48P July 2005...
  • Page 2: Table Of Contents

    CONTENTS Important Owner Information_____________________________________1 Introduction____________________________________________________1 Important Safety Instructions___________________________________2 Model Description_______________________________________________3 Specifications__________________________________________________3 Plug Configurations_____________________________________________3 Installation____________________________________________________4 Start-up Procedure______________________________________________5 Troubleshooting Guide___________________________________________6 Recommended Cleaning and Sanitizing_____________________________7 Dual Probe Liquid Level Controller______________________________8 Components Tests________________________________________________9 Hopper Assembly________________________________________________10 Whipper Chambers_______________________________________________11 Body Frame_____________________________________________________12 Electrical Chassis_____________________________________________21 Upper Door_____________________________________________________22 Lower Door_____________________________________________________23 Hot Water Tanks________________________________________________24 Electrical diagram_____________________________________________26...
  • Page 3: Important Owner Information

    Additional information can be found by visiting our web site at www.cecilware.com INTRODUCTION The Cecilware 5, 6, & 8 head instant Cappuccino Dispenser is designed to meet the exact needs of the Convenience Store atmosphere. Cecilware has led the way in the highly profitable and growing market of Cappuccino with its GB series of Automatic Cappuccino Dispensers.
  • Page 4: Important Safety Instructions

    To avoid any injury, turn both power switches OFF. Or, unplug both power cords and allow unit to cool completely before performing any maintenance or cleaning. The GB5MV-10-LD and GB6MP-10-LD-U are equipped with one (1) power switch and one (1) 120 volt grounded power cord.
  • Page 5: Model Description

    Only Cecilware brings you this type of versatility. With its top hinged and bottom hinged door design, its 27 inch footprint (left to right) allows maximum utilization of counter space.
  • Page 6: Installation

    GB8MP-10-LD-U: There are two (2) Water Connections. (2) ¼ inch Flare Water Inlet Fittings are located on the left and right side in the back of unit. GB5MV-10-LD, & GB6MP-10-LD-U: There is one (1) Water Connection, (1) ¼ inch Flare Water Inlet Fitting located on the back of unit.
  • Page 7: Start-Up Procedure

    START-UP PROCEDURE Caution: Make sure that the Heater Switches, are in the OFF position. 1. Connect the ¼ inch copper waterlines to the ¼ inch flare water inlet fittings of the valves. 2. Plug the power cords into dedicated receptacles. 3.
  • Page 8: Troubleshooting Guide

    WARNING: To reduce the risk of electrical shock, or replacing any internal components of the unit. Before any attempt to replace a component be sure to check all electrical connections for proper connection. PROBLEM PROBABLE CAUSE Dispensing unit unplugged. Light display No power from Terminal Block.
  • Page 9: Recommended Cleaning And Sanitizing

    Model L690A (Rev. B) Dual Probe Liquid Level Controller Overview - The L690A is a Dual Probe Liquid Level Controller designed to maintain a specific level of water in the tank. This device utilizes two level probes for increased reliability. Independent maximum fill timers are incorporated in the controller for overflow protection.
  • Page 10 1. ROTATE PRODUCT GUIDES UP, REMOVE HOPPERS AND REFILL WITH PRODUCT. 2. REPLACE HOPPERS, ROTATE PRODUCT GUIDES DOWN. 3. EMPTY DRIP TRAY. 4. SANITIZE* ALL EXTERIOR SURFACES. 1. PRODUCT HOPPER CLEANING - ROTATE PRODUCT GUIDES UP, REMOVE HOPPERS FROM MACHINE. - EMPTY POWDER INTO PANS.
  • Page 12: Hopper Assembly

    GB5MV-10-LD (VISTA) 5 Flavor Cappuccino Dispenser Door not shown HOPPER (4) (CD185) PRODUCT GUIDE POWER SWITCH RINSE SWITCH GRILL DRIP TRAY HOPPER (1) (CD179) HEATER LIGHT HEATER SWITCH WHIPPER CHAMBER...
  • Page 14: Whipper Chambers

    WHIPPER CHAMBER IMPORTANT: SLANTED WHIPPER CHAMBERS (SEE BELOW) ARE NOT INTERCHANGEABLE WITH STANDARD STRAIGHT WHIPPER CHAMBERS. BE SURE TO ORDER USING THE CORRECT PART NUMBERS. ITEM IMPELLER (1 FLAT) USE W/ CD75A) IMPELLER (2 FLATS) USE W/ CD75A OR CD350 SLANTED WHIPPER CHAMBER...
  • Page 15 HOPPER COVER AGITATOR WHEEL W/SPRINGS AUGER MOTOR #CD175 (90 RPM) AUGER BUSHING FRONT CD306 NUT CD278 [2] BEVELLED SOCKET CD271 PRODUCT GUIDE, SHORT AUGER BUSHING-BACK CD279 CD70A HOPPER BASE CD140...
  • Page 16 HOPPER COVER AGITATOR WHEEL W/SPRINGS AUGER MOTOR #CD175 (90 RPM) AUGER BUSHING FRONT CD306 NUT CD278 [2] BEVELLED SOCKET CD271 PRODUCT GUIDE, SHORT AUGER BUSHING-BACK CD279 CD70A HOPPER BASE CD140...
  • Page 22 TANK DIMENSIONS: 12" WIDE, 4.8" DEEP, 16.5" HIGH. APPROX. 3.7 GAL. ITEM DESCRIPTION...
  • Page 23: Electrical Chassis

    TANK DIMENSIONS: 15" WIDE, 6" DEEP, 18" HIGH. APPROX. 6 GAL. ITEM DESCRIPTION...
  • Page 24: Upper Door

    BREW BREW SWITCH SWITCH DOOR UNIT MAIN UNIT RINSE SWITCH AUGER CONTACTOR RELAY WATER INLET TANK HEATER 1.7KW 5-15R GB5-LD-U 15A-1.7KW BREW SWITCH DISPENSE DISPENSE VALVE VALVE AUGER WHIPPER WHIPPER RELAY RELAY VALVE LIQUID LEVEL CONTROL WATER LEVEL PROBES WATER HI-LIMIT THERMOSTAT 5-15P...
  • Page 25: Lower Door

    GB6M-10-LD-U...
  • Page 26: Hot Water Tanks

    WATER LEVEL PROBES WATER GB8M-10-LD-U & GB8M10WLD ELECTRICAL DIAGRAM - LEFT SIDE - 120V DISPLAY LIGHTS LIQUID LEVEL CONTROL REV A NE195 SHEET 1 OF 2...
  • Page 27 WATER LEVEL PROBES WATER GB8M-10-LD-U & GB8M10WLD ELECTRICAL DIAGRAM - RIGHT SIDE - 120V DISPLAY LIGHT LIQUID LEVEL CONTROL REV A NE195 SHEET 2 OF 2...

This manual is also suitable for:

Panorama gb6mp-10-ld-uPanorama gb8mp-10-ld-u

Table of Contents