MHV 2 UL AF 1 TECHNICAL CHARACTERISTICS Transparent removable bowls Capacity of each bowl, approx. Dimensions: width depth height Net weight, approx. Gross weight, approx. Adjustable thermostats Hermetic compressors Air-cooled condensers Overload protectors Safety pressure switches Noise level lower than 70 dB (A) IMPORTANT Read electrical ratings written on the data plate of the individual units;...
For soft drinks the bases are to be diluted with more water, on a 1 plus 5/5.5 basis. In any case follow the syrup manufacturer’s instructions for both Granita and soft drink recipes. If natural juices (e.g. lemon, orange) as well as sugarless products (e.g.
MHV 2 UL AF (the indicator F will go up in opening G). figure 3 2 - Beverage temperature adjustment: proper beverage temperature is factory preset. To reset, turn the knob loca- ted in each switch box as follows: - toward right (clockwise) to decrease temperature. -toward left (counterclockwise) to increase temperature.
figure 6 3 - Slide the outer spiral out (see figure 7) and then the inside auger (see figure 8). figure 7 figure 8 4 - Remove the bowl gasket from its seat (see figure 9). figure 9 Ugolini spa 5 - Dismantle the faucet assembly (see figure 10).
MHV 2 UL AF 5. 3. 3 SANITIZING Sanitizing should be performed immediately prior to starting the machine. Do not allow the unit to sit for extended periods of time after sanitization. 1 - Wash hands with a suitable antibacterial soap. 2 - Prepare at least two gallons of a warm (45-60 °C 120- 140 °F) sanitizing solution (100 PPM available chlorine concentration or 1 spoon of sodium hypoclorite diluted with...
2 - Pour the solution into the bowl(s). 3 - Using a brush suitable for the purpose, wipe the solution on all surfaces protruding above the solution-level and on the underside of the top cover(s). 4 - Install the top cover(s) and operate the unit. Allow the solu- tion to agitate for about two minutes.
MHV 2 UL AF flow charts”. 8. 1 INSTALLATION 1 - Loosen the fitting locker located on the rear cover of each bowl equipped with Autofill Device and connect the remote fill system using a 1/4” fitting suitable to the purpose. Tighten the fitting locker.
tion. 3 - Set the unit mixer/refrigeration switch of the bowl to II position. Note: when Autofill switch is set to position 0, the unit performs as a standard unit not equipped with Autofill Device. 8. 2. 2 OPERATIONAL HELPFUL HINTS 1 - When the remote fill system is equipped with Sold-out switches if a product sold-out occurs the Autofill Device automatically stops and acoustic and visual alarms are...
Page 12
SPARE PARTS LIST 2430_49 V 2.8 07D11 MHV 2 UL AF...