approved lubricant.
3 - Assemble the faucet by reversing the disassembly steps
(see figure 10)
4 - Fit bowl gasket around its seat.
Note: the largest brim of gasket must face against the rear
wall (see figure 12).
5 - Insert the auger into the evaporator. Taking care to insert
the rear seal properly. (see figure 13).
6 - Install the outer spiral. Slide it over the evaporator until its
Ugolini spa
figure 11
figure 12
figure 13
front notch engages with the exposed end of the auger
shaft (see figure 14).
7 - Push the bowl towards the rear wall of the unit until it fits
snugly around the gasket and its front fastening hooks are
properly engaged (see figure 15).
8 - Use fresh product to chase any remaining sanitizer from
the bottom of the bowl(s). Drain this solution. Do not rinse
out the machine.

5. 4 IN-PLACE SANITIZATION

The In-Place Sanitization prior to starting the machine may be
performed, if needed, only as further precaution, in addition to
the Disassembled Parts Sanitization described before, but
never in lieu of it.
1 - Prepare two gallons of a warm (45-60°C / 120-140 °F)
s a n i t i z i n g s o l u t i o n ( 1 0 0 P P M a v a i l a b l e c h l o r i n e
concentration or 1 spoon of sodium hypoclorite diluted with
half a gallon of water) according to your local Health
Codes and manufacturer's specifications.
2 - Pour the solution into the bowl(s).
3 - Using a brush suitable for the purpose, wipe the solution
NHT UL AF BL
figure 14
figure 15
9