Maintenance (To Be Carried Out By Qualified Service Personnel Only); Defrost Timer (Optional) - Cecilware MT-2-ULAF Operator's Manual

Cecilware mt-2-ulaf dispensers: user guide
Hide thumbs Also See for MT-2-ULAF:
Table of Contents

Advertisement

Available languages

Available languages

MT UL AF Black
the two plastic coated screws (see figure 17).
3 - Replacement of lighted top cover bulb: remove the fixing
screw placed in the upper part of the top cover, remove the
lower part and replace the bulb (using a 24-28V 21W max
bulb). Reassemble the top cover and replace the fixing
screw.(vedere figure 18)
ATTENTION
Condenser fins are very sharp. Use extreme caution
when cleaning.
6. 1 MAINTENANCE (TO BE CARRIED OUT
BY QUALIFIED SERVICE PERSONNEL
ONLY)
1 - Monthly on MT 1 model: remove the dust from the
condenser. To do this unplug the unit or switch off the 2-
pole wall breaker and then remove the panels.
2 - Annually: remove the panels and clean the inside of the
machine including the base, side panels, condenser, etc.
3 - In order to prevent any damages to the dispenser, all
plastics parts must be lubricated only with grease supplied
by the manufacturer or with another lubricating product
suitable for polycarbonate.
IMPORTANT
The electric diagram of the dispenser is located in the
inner part of the dispensing side panel.

7 DEFROST TIMER (OPTIONAL)

The Defrost Timer, located on the right side of the unit,
10
figure 17
figure 18
automatically switches the dispenser from Granita mode to
Soft Drink mode and the opposite. This means that during
defrost periods frozen Granita will melt to thermostat setting
temperature and once defrost period has expired, the product
automatically freezes down again to Granita setting viscosity.
To operate the defrost timer proceed as follows (see figure 19).
1 - Set the time of the day by rotating the dial clockwise (arrow
A). Never rotate the timer counterclockwise as this
would damage the internal mechanism. Align the current
time of day with the arrow B on the timer face. This is a 24
hour timer showing both A.M. and P.M.
2 - Program the defrost timer by pushing out on the tabs C
that correspond to the hours desired to defrost. Each tab
represents 15 minutes. A minimum of four to eight hours
are required to defrost frozen beverage (depending on
ambient conditions).
Note: when all the tabs are pushed in the defrost function is
OFF (the machine operates as if it were not equipped with
Defrost Timer).