Input of formatted commands

D000030108 en m – E650 Series 3 – ZMD300AT/CT – User Manual
The sender feeds these objects to a transport medium, e.g. the telephone
network. This transmits them to the receiver, so that the objects are
received in the same form as supplied by the sender.
The following operating data or meter characteristics can be modified by
the input of formatted commands. The user of formatted commands,
however, must have the necessary access authorisation according to the
security system.
The following commands can be used both according to IEC 62056-21 and
also with DLMS:
Set time/date
Set identification numbers for the energy supply company and for the
manufacturer (by line).
Reset
Neutralise reset inputs KA/KB
Set/reset reset counter
Control tariff rates via interface
Set/reset energy registers
Set/reset total energy registers
Set/reset demand maximum registers
Set/reset power factor registers
Reset stored values
Reset battery hours counter
Reset voltage failures registers
Switch on/off increased resolution (test mode) of energy registers
Define by additional parameters whether the optical test output for
active energy in test mode supplies active or reactive energy pulses
Delete error messages
Change passwords P1,P2 and W5
Reset load profile 1 / load profile 2
Reset event log
Reset dedicated event log groups
The following commands can only be executed with DLMS:
Reset event register
– Under- and over-voltages
– Demand messages
– Current messages
– Power factor messages
Set thresholds for messages