LP GAS REQUIREMENTS
NOTE:
An enclosure for an LP gas cylinder shall be vented by openings at the level
of the cylinder valve and at floor level. The effectiveness of the opening(s) for
purposes of ventilation shall be determined with the LP-gas supply cylinder in
place. This shall be accomplished in one of the following manners:
1)
One side of the enclosure shall be completely open; or
2)
Enclosures that have four sides, complete with a top and bottom:
a.
At least two ventilation openings at cylinder valve level shall be provided in the
sidewall, equally sized, spaced at 180 degrees (3.14 rad), and unobstructed.
Each opening shall have a total free area of not less than fi" square inch per
pound (7.1 cm≈/kg) of stored fuel capacity, and not less than a total free area
of 10 square inches (64.5 cm≈).
b.
Ventilation opening(s) shall be provided at floor level and shall have a total
free area of not less than fi square inch per pound (7.1 cm≈/kg) of stored fuel
capacity and not less than a total free area of 10 square inches (64.5cm≈). If
ventilation openings at floor level are in a sidewall, there shall be at least two
openings. The bottom of the openings shall be at floor level and the upper
edge no more than 5 inches (127 mm) above the floor. The openings shall be
equally sized, spaced at 180 degrees (3.14 rad) and unobstructed.
c.
Every opening shall have minimum dimensions so as to permit the entrance of
a 1/8 inch (3.2 mm) diameter rod.
LP Gas Manifold Pressure
For plumbed-in LP installation, use a convertible regulator and set it for LP gas.
LP Gas Supply Pressure
Maximum line pressure for plumbed in Propane is 14" W.C., fi psi (3.5 kPa).
Minimum line pressure for propane is 11" W.C.
LP Gas Pressure Regulator
The unit must be used with the gas pressure regulator. The regulator will control and
maintain a uniform gas pressure in the manifold. The burner orifices have been sized for
the gas pressure delivered by the regulator.