Grounding Cable.
5.2.1.4 Dismantle the control Module's fix screw of left and right side. And dismantle the fix metal
brackets.
5.2.1.5 Move the control module and each battery module one by one.
Danger: when battery is connected
together with the base the internal
socket still have high voltage DC
power from serial connected
battery modules (battery module
can't be turned off).
Handle above the red marked edgings of the both side of these battery modules and control
module (BMS).
Caution: If hands under this red marked side, hands will get hurt.
Warning: Single battery module is 35kg. If without handling tools must more than 2 men to
handling with it.
5.2.1.6 Pile up the new battery module. And pile up the battery modules and control module up